Dual-purpose sample trap for on-line strong cation-exchange chromatography/reversed-phase liquid chromatography/tandem mass spectrometry for shotgun proteomics. Application to the human Jurkat T-cell proteome.
نویسندگان
چکیده
A dual-purpose sample-trapping column is introduced for the capacity enhancement of proteome analysis in on-line two-dimensional nanoflow liquid chromatography (strong cation-exchange chromatography followed by reversed-phase liquid chromatography) and tandem mass spectrometry. A home-made dual trap is prepared by sequentially packing C18 reversed-phase (RP) particles and SCX resin in a silica capillary tubing (1.5 cm x 200 microm I.D. for SCX, 0.7 cm x 200 microm for RP) ended with a home-made frit and is connected to a nanoflow column having a pulled tip treated with an end frit. Without having a separate fraction collection and concentration process, digested peptide mixtures were loaded directly in the SCX part of the dual trap, and the SCX separation of peptides was performed with a salt step elution initiated by injecting only 8 microL of NH4HCO3 solution from the autosampler to the dual trap. The fractionated peptides at each salt step were directly transferred to the RP trap packed right next to the SCX part for desalting, and a nanoflow LC-MS-MS run was followed. During the sample loading-SCX fractionation-desalting, flow direction was set to bypass the analytical column to prevent contamination. The entire 2D-LC separation and MS-MS analysis were automated. Evaluation of the technique was made with an injection of 15 microg peptide mixtures from human Jurkat T-cell proteome, and the total seven salt step cycles followed by each RPLC run resulted in an identification of 681 proteins.
منابع مشابه
Automated injection of uncleaned samples using a ten-port switching valve and a strong cation-exchange trap column for proteome analysis.
Nanoliter flow rate is optimum for separation in capillary column liquid chromatography coupled with tandem mass spectrometry (muHPLC-MS/MS). In order to develop a high-performance automated proteome analysis system allowing direct injection sample containing detergents, the influence of void volume varied from 0 to 5 microL on the separation performance and proteomic coverage of sample injecti...
متن کاملCapillary trap column with strong cation-exchange monolith for automated shotgun proteome analysis.
A 150 microm internal diameter capillary monolithic column with a strong cation-exchange stationary phase was prepared by direct in situ polymerization of ethylene glycol methacrylate phosphate and bisacrylamide in a trinary porogenic solvent consisting dimethylsulfoxide, dodecanol, and N,N'-dimethylformamide. This phosphate monolithic column exhibits higher dynamic binding capacity, faster kin...
متن کاملOnline nanoflow reversed phase-strong anion exchange-reversed phase liquid chromatography-tandem mass spectrometry platform for efficient and in-depth proteome sequence analysis of complex organisms.
The dynamic range of protein expression in complex organisms coupled with the stochastic nature of discovery-driven tandem mass spectrometry (MS/MS) analysis continues to impede comprehensive sequence analysis and often provides only limited information for low-abundance proteins. High-performance fractionation of proteins or peptides prior to mass spectrometry analysis can mitigate these effec...
متن کاملInsulin stimulated MCF7 breast cancer cells: Proteome dataset
The proteome data provided in this article were acquired from MCF7 breast cancer cells stimulated with insulin, and were generated by using a 2D-SCX (strong cation exchange)/RPLC (reversed phase liquid chromatography) separation protocol followed by tandem mass spectrometry (MS) detection. To facilitate data re-processing by more advanced search engines and the extraction of additional informat...
متن کاملAdditions to the Human Plasma Proteome via a Tandem MARS Depletion iTRAQ-Based Workflow
Robust platforms for determining differentially expressed proteins in biomarker and discovery studies using human plasma are of great interest. While increased depth in proteome coverage is desirable, it is associated with costs of experimental time due to necessary sample fractionation. We evaluated a robust quantitative proteomics workflow for its ability (1) to provide increased depth in pla...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 1070 1-2 شماره
صفحات -
تاریخ انتشار 2005