Anterior corneal asphericity calculated by the tangential radius of curvature.

نویسندگان

  • Jinglu Ying
  • Bo Wang
  • Mingguang Shi
چکیده

We propose a method of calculating the corneal asphericity (Q) and analyze the characteristics of the anterior corneal shape using the tangential radius. Fifty-eight right eyes of 58 subjects were evaluated using the Orbscan II corneal topographer. The Q-values of the flat principal semi-meridians calculated by the sagittal radius were compared to those by the tangential radius. Variation in the Q-value with semi-meridian in the nasal and temporal cornea calculated by the tangential radius was analyzed. There were significant differences in Q-values (P<0.001) between the two methods. The mean Q-values of the flat principal semi-meridians calculated by tangential radius with -0.33 ± 0.10 in the nasal and -0.22 ± 0.12 in the temporal showed more negative than the corresponding Q-values calculated by the sagittal radius. The Q-values calculated by tangential radius became less negative gradually from horizontal semi-meridians to oblique semi-meridians in both nasal and temporal cornea. Variation in Q-value with semi-meridian was more obvious in the nasal cornea. The method of calculating corneal Q using the tangential radius could provide more reasonable and complete Q-value than that by the sagittal radius. The model of a whole anterior corneal surface could be reconstructed on the basis of the above method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comprehensive Evaluation of Anterior Corneal Change in Asphericity Calculated by the Tangential Radius of Curvature after LASIK

To evaluate the change in the anterior corneal asphericity (ΔQ) comprehensively calculated using the tangential radius (rt ) after LASIK. Forty-two right eyes were evaluated using the Orbscan II corneal topographer. The pre- and postoperative Q-values of the flat principal semimeridians calculated by the sagittal radius were compared to those by the tangential radius. The Q-value of each semime...

متن کامل

Three-dimensional model for human anterior corneal surface.

The anterior corneal asphericity (Q) with the tangential radius is calculated, and a three-dimensional (3-D) anterior corneal model is constructed. Tangential power maps from Orbscan II are acquired for 66 young adult subjects. The Q-value of each semimeridian in the near-horizontal region is calculated with the tangential radius. Polynomial fitting is used to model the 360-semimeridional varia...

متن کامل

The 3D Computer Image of the Anterior Corneal Surface

In this paper, we derive a nonlinear equation of corneal asphericity (Q) using the tangential radius of curvature (rt) on every semi-meridian. We transform the nonlinear equation into the linear equation and then obtain the Q-value of corneal semi-meridian by the linear regression method. We find the 360 semi-meridional variation rule of the Q-value using polynomial function. Furthermore, we co...

متن کامل

The shape of the anterior and posterior surface of the aging human cornea

PURPOSE To determine the shape and astigmatism of the posterior corneal surface in a healthy population with age, using Scheimpflug photography corrected for distortion due to the geometry of the Scheimpflug imaging system and the refraction of the anterior corneal surface. METHODS Scheimpflug imaging was used to measure in six meridians the cornea of the right eye of 114 subjects, ranging in...

متن کامل

Equation for corneal asphericity after corneal refractive surgery.

PURPOSE To determine the exact theoretical asphericity after refractive surgery when the parabolic approximation of the Munnerlyn formula is utilized. METHOD From a least-square analysis and considering the conicoid model for anterior cornea, we calculated the final asphericity (p'-factor) from the preoperative asphericity and the radii before and after surgery. RESULTS The final p'-factor ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomedical optics

دوره 17 7  شماره 

صفحات  -

تاریخ انتشار 2012