Accuracy of pelvic flexion measurements from lateral radiographs.

نویسندگان

  • Kort Eckman
  • Mahmoud A Hafez
  • Frcs Ed
  • Branislav Jaramaz
  • Timothy J Levison
  • Anthony M Digioia
چکیده

Variations in pelvic orientation affect preoperative planning decisions, intraoperative navigation, and postoperative measurements. By providing the means to measure pelvic flexion at low cost and reporting pelvic flexion using the standard reference system, a lateral radiograph technique based on the pubic tubercles and anterior superior iliac spines may be useful for studying functional pelvic orientation and functional alignment and for improving accuracy of postoperative measurement. We evaluated the accuracy of this method by synthesizing 50 lateral pelvic radiographs. Six observers performed manual landmark-based pelvic flexion measurements on the resultant radiographs. Pelvic flexion measurement errors were small (0.004 masculine +/- 1.38 masculine). Apart from one outlier with an error of 12.4 masculine, the errors ranged from -4.0 masculine to 3.0 masculine. The data suggest that accurate measurements of pelvic flexion can be made from lateral radiographs with respect to the standard anatomic reference system. However, failure to correctly observe a landmark can introduce large errors. Therefore, the clarity of the relevant landmarks should be considered carefully before applying this technique. Lateral radiographs can be easily acquired and analyzed, making this technique convenient and inexpensive.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measuring acetabular component version after THA: CT or plain radiograph?

BACKGROUND Although cross-table lateral radiographs are commonly used to measure acetabular component version after THA, recent studies suggest that CT-based measurement is more accurate. This has been attributed to variations in pelvic tilt, pelvic rotation, and component inclination. Furthermore, it has been suggested, based on limited data, that even with ideal positioning of the cross-table...

متن کامل

Reliability Analysis of Spino-Pelvic Parameters in Adult Spinal Deformity: A Comparison of Whole Spine and Pelvic Radiographs.

STUDY DESIGN Retrospective study. OBJECTIVE To examine the reliabilities of sagittal spino-pelvic alignment measurements using whole spine-pelvic and local pelvic radiographs and to determine whether spinal deformity affects these reliabilities. SUMMARY OF BACKGROUND DATA Sagittal spino-pelvic alignment is important in adult spinal deformity patients (ASD). Spino-pelvic parameters are close...

متن کامل

2D/3D Registration for Measurement of Implant Alignment After Total Hip Replacement

Measurements of cup alignment after total hip replacement (THR) surgery are typically performed on postoperative pelvic radiographs. Radiographic measurement of cup orientation depends on the position and orientation of the pelvis on the X-ray table, and its variability could introduce significant measurement errors. We have developed a tool to accurately measure 3D implant orientation from pos...

متن کامل

The effects of bite line deviation on lateral cervical radiographs when upper cervical joint dysfunction exists: a pilot study.

PURPOSE To demonstrate the impact of inconsistent bite line positioning during pre and post lateral cervical radiographic examinations and to suggest certain additional imaging studies if the bite line cannot be consistently maintained. METHODS Radiographic measurements of relative flexion and extension in the atlantal-occipital (AO) and atlantal-axial (AA) joints were taken from neutral late...

متن کامل

Poor accuracy of plain radiographic measurements of prosthetic migration and alignment in total ankle replacement

BACKGROUND The rotational position of the leg substantially influences measurements in ankle radiographs after total ankle replacement (TAR). The aim of our study was to further specify the influence of different projections on radiographic parameters used to assess component position after TAR. METHODS The effect of varying degrees of internal rotation, flexion, and ab-/adduction on referenc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 451  شماره 

صفحات  -

تاریخ انتشار 2006