BACKGROUND Suitable procedures for transport of blood samples from general practitioners to hospital laboratories are requested. Here we explore routine testing on samples stored and transported as whole blood in lithium-heparin or serum tubes. METHODS Blood samples were collected from 106 hospitalized patients, and analyzed on Architect c8000 or Advia Centaur XP for 35 analytes at base line, and after storage and transport of whole blood in lithium-heparin or serum tubes at 21 ± 1°C for 10 h. Bias and imprecision (representing variation from analysis and storage) were calculated from values at baseline and after storage, and differences tested by paired t-tests. Results were compared to goals set by the laboratory. RESULTS We observed no statistically significant bias and results within the goal for imprecision between baseline samples and 10-h samples for albumin, alkaline phosphatase, antitrypsin, bilirubin, creatinine, free triiodothyronine, γ-glutamyl transferase, haptoglobin, immunoglobulin G, lactate dehydrogenase, prostate specific antigen, total carbon dioxide, and urea. Alanine aminotransferase, amylase, C-reactive protein, calcium, cholesterol, creatine kinase, ferritin, free thyroxine, immunoglobulin A, immunoglobulin M, orosomucoid, sodium, transferrin, and triglycerides met goals for imprecision, though they showed a minor, but statistically significant bias in results after storage. Cobalamin, folate, HDL-cholesterol, iron, phosphate, potassium, thyroid stimulating hormone and urate warranted concern, but only folate and phosphate showed deviations of clinical importance. CONCLUSIONS We conclude that whole blood in lithium-heparin or serum tubes stored for 10 h at 21 ± 1°C, may be used for routine analysis without restrictions for all investigated analytes but folate and phosphate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability of free beta-hCG in the routine screening of Down syndrome in the first trimester of pregnancy.

Stability of free beta-human chorionic gonadotropin in maternal blood upon storage at ambient and refrigerator temperatures as well as stability under conditions simulating postal transport were studied. A group of 26 women in the first trimester of pregnancy were included in the study, blood samples were taken during the routine check-up. Blood samples were aliquoted stored in different condit...

متن کامل

Comparative evaluation of five different storage media and temperature effect on human periodontal ligament fibroblast viability

Introduction: Following dental avulsion, the immediate recommended treatment is tooth replantation to avoid adverse effects. Therefore, the tooth must be stored in a physiological storage medium to preserve the viability of the periodontal ligament fibroblast (PDLF) cells during transportation to dental office. The aim of this study was to determine the effect of several storage media in preser...

متن کامل

Evaluation of germination and some biochemical indices of faba bean (Vicia faba L.) seeds stored at different temperatures and moisture content

This study was performed to investigate the effect of storage conditions on seed germination performance of faba bean (cv. Shami). For this purpose, a three factors factorial experiment was conducted in laboratory of Seed Science and Technology, Faculty of Agriculture, Yasouj University, in 2013-2014, based on CRD design with five replications.  The experimental factors were storage temperature...

متن کامل

The Effect of Incubation Time on the Activity and Stability of Factor VIII during the Preparation Process

Background and Aims: Hemophilia is a rare autoimmune disorder caused by autoantibodies directed in the majority of the cases against clotting factor VIII (FVIII). FVIII is extracted from human plasma or engineered from mammalian cell cultures using recombinant DNA technology. In Iran, most of the used FVIII is prepared from human plasma in Iranian Blood Transfusion Organization. It was seen imp...

متن کامل

Whether regular working hours can minimize the blood biochemical effects of shift working: a cross-sectional study in Iran

  Abstract   Background: Irregular Working hours, including night work and shift work, have been   found to be associated with alteration in various levels of biochemical factors. And some studies have showed association between shift work and blood biochemical disturbances in blood. In this epidemiological study we investigated, whether regular schedule of working hours can minimize the associ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 74  شماره 

صفحات  -

تاریخ انتشار 2014