Factors affecting the efficiency of aerosol therapy with pressurised metered-dose inhalers through plastic spacers.

نویسندگان

  • A A Chuffart
  • F H Sennhauser
  • J H Wildhaber
چکیده

AIM The main objective of this study was to compare the in vitro delivery of salbutamol from a chlorofluorocarbon(CFC)-propelled pressurised metered-dose inhaler (pMDI) versus a newly developed hydrofluoroalkane(HFA)-propelled pMDI through various spacers. In addition, we aimed to study the effect on bronchodilator response when using an optimal pMDI/spacer combination for aerosol delivery compared to a suboptimal combination. METHODS Particle size distribution and output from salbutamol pMDIs containing either CFC propellants (Ventolin) or HFA propellants (Airomir) were measured using a multistage liquid impinger (MSLI) and compared to that through both detergent-coated (non-static) or untreated (static) large volume (Nebuhaler, Volumatic) and small volume (Aerochamber) plastic spacers. Flow-volume curves (FEV1) were obtained from twelve asthmatic children with known significant bronchodilator response (8 males), aged 13-17 years, randomly inhaling salbutamol from a CFC-pMDI through a static spacer (Nebuhaler) and from an HFA-pMDI through a non-static spacer (Nebuhaler). RESULTS In vitro output of particles in the respirable range (< 6.8 microns) from HFA-pMDIs was significantly higher than that from CFC-pMDIs using various spacers. Removal of electrostatic charge increased output from CFC- and HFA-pMDIs through all spacers by 17-82%. The mean (SD) bronchodilator response after inhalation of salbutamol from a CFC-pMDI through a static spacer was 7.1% (6.3%) compared to 17.5% (7.9%) after inhalation from an HFA-pMDI through a non-static spacer (p = 0.002). CONCLUSIONS Use of a newly developed HFA-propelled pMDI greatly improves drug delivery through spacers compared to a CFC-propelled pMDI. However, electrostatic charge in plastic spacers remains the key determinant limiting delivery of salbutamol from a pMDI through spacers, and can be reduced by soaking the spacer in a household detergent. Using an optimal pMDI/spacer combination leads to a significantly improved bronchodilator response.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Rationale for Going Back to the Future: Use of Disposable Spacers for Pressurised Metered Dose Inhalers

The introduction of pressurised metered dose inhalers (MDIs) in the mid-1950s completely transformed respiratory treatment. Despite decades of availability and healthcare support and development of teaching aids and devices to promote better use, poor pMDI user technique remains a persistent issue. The main pMDI user aid is the spacer/valved holding chamber (VHC) device. Spacer/chamber features...

متن کامل

Systematic review of clinical effectiveness of pressurised metered dose inhalers versus other hand held inhaler devices for delivering corticosteroids in asthma.

OBJECTIVE To determine the clinical effectiveness of pressurised metered dose inhalers (with or without spacer) compared with other hand held inhaler devices for the delivery of corticosteroids in stable asthma. DESIGN Systematic review of randomised controlled trials. DATA SOURCES Cochrane Airways Group trials database (Medline, Embase, Cochrane controlled clinical trials register, and han...

متن کامل

Incorrect use of pressurised metered dose inhaler by asthmatic patients.

The use of pressurised metered dose inhalers was assessed among 93 asthmatic patients attending the respiratory out patient clinic between January to October 1989. They were regular users of the inhalers prior to the assessment. 62.4% of the patients were found to use the inhalers incorrectly. Forty three percent made more than one error. The commonest error observed was the failure to actuate ...

متن کامل

A non-electrostatic spacer for aerosol delivery.

A pear shaped non-electrostatic spacer, composed of steel with a volume of 250 ml and equipped with a facemask containing integrated inlet and outlet valves for inspiration and expiration, was compared with three plastic spacers. The plastic spacers were primed with repeated puffs from a budesonide pressurised metered dose inhaler (p-MDI) to minimise the electrostatic charge on the plastic. The...

متن کامل

Pressurised metered dose inhalers with spacers versus nebulisers for beta-agonist delivery in acute asthma in children in the emergency department.

OBJECTIVES Wet nebulisers are widely used for beta-2 agonist delivery in Australasian emergency departments (ED). An increasing body of work suggests that pressurised metered dose inhalers with spacers (pMDI-S) are as effective. This study aims to investigate the effect on admission rates, total time in the ED, and total time in hospital after initiation of routine pMDI-S treatment for mild to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Swiss medical weekly

دوره 131 1-2  شماره 

صفحات  -

تاریخ انتشار 2001