Interface pressure sensor for IVRA and other biomedical applications.
نویسندگان
چکیده
The fabrication and testing of a minimally intrusive (2 mm high, 10 mm diameter) biomedical interface pressure sensor are described. Such sensors are needed for the implementation of improved safety features in the next generation of automated intravenous regional anaesthesia (IVRA) systems. The sensor utilizes a structured elastomer as a deflection element sandwiched between the plates of a parallel plate capacitor device. Simple mechanical modifications allow sensitivity and zero offset adjustment. The sensor is housed in a package machined from an engineering polymer. The device is easily calibrated using either a bench-top or an on-body calibration procedure. The device is particularly sensitive to cuff artefacts arising from variations in cuff-wrap tightness and folding of the cuff. As such, it offers some promise for detecting potential hazard conditions which can occur during conventional IVRA procedures. For the purpose of unit conversion, 1 Pa = 1 N/m2, 1 MPA = 1 N/mm2 and 40 kPa approximately equal to 300 mmHg.
منابع مشابه
New Design of Mems piezoresistive pressure sensor
The electromechanical analysis of a piezoresistive pressure microsensor with a square-shaped diaphragm for low-pressure biomedical applications is presented. This analysis is developed through a novel model and a finite element method (FEM) model. A microsensor with a diaphragm 1000 „m length and with thickness=400 µm is studied. The electric response of this microsensor is obtained with applyi...
متن کاملDetection of Fuel Adulteration in Real Time Using Optical Fiber Sensor and Peripheral Interface Controller
Detection of fuel adulteration in real time is the most important need of the world as it generates the hazardous effects on the environment, living and nonliving things. Various automotive users and fuel providers may mix kerosene in petrol and diesel. Adulterated fuel increases air pollution, as well as reduces the performance of vehicle engines. Such a malpractice in fuel is prevailing becau...
متن کاملمقایسه اثرات پیشداروی کلونیدین خوراکی با کلونیدین تزریقی اضافه شده به محلول لیدوکایین بر مدت بیدردی بلوک بییر در اعمال جراحی محیطی اندام فوقانی
Background and Aim: Clonidine has been found to decrease the tourniquet pain and enhance analgesia, when added to lidocaine in Intravenous Regional Anesthesia (IVRA) for upper extremity surgery. Our study evaluates the efficacy of oral clonidine as premedication before IVRA with that of lidocaine for upper extremity surgery and compares it to that of clonidine added as adjunct to lidocaine ...
متن کاملDesign of a Programmable Passive SoC for Biomedical Applications Using RFID ISO 15693/NFC5 Interface
Low power, low cost inductively powered passive biotelemetry system involving fully customized RFID/NFC interface base SoC has gained popularity in the last decades. However, most of the SoCs developed are application specific and lacks either on-chip computational or sensor readout capability. In this paper, we present design details of a programmable passive SoC in compliance with ISO 15693/N...
متن کاملDesign and Modeling of a New Type of Tactile Sensor Based on the Deformation of an Elastic Membrane
This paper presents the design and modeling of a flexible tactile sensor, capable of detecting the 2D surface texture image, contact-force estimation and stiffness of the sensed object. The sensor is made of polymer materials. It consists of a cylindrical chamber for pneumatic actuation and a membrane with a mesa structure. The inner radius of the cylindrical chamber is 2cm and its outer radius...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical engineering & physics
دوره 26 2 شماره
صفحات -
تاریخ انتشار 2004