Fringe Capacitance Correction for a Coaxial Soil Cell
نویسندگان
چکیده
Accurate measurement of moisture content is a prime requirement in hydrological, geophysical and biogeochemical research as well as for material characterization and process control. Within these areas, accurate measurements of the surface area and bound water content is becoming increasingly important for providing answers to many fundamental questions ranging from characterization of cotton fiber maturity, to accurate characterization of soil water content in soil water conservation research to bio-plant water utilization to chemical reactions and diffusions of ionic species across membranes in cells as well as in the dense suspensions that occur in surface films. One promising technique to address the increasing demands for higher accuracy water content measurements is utilization of electrical permittivity characterization of materials. This technique has enjoyed a strong following in the soil-science and geological community through measurements of apparent permittivity via time-domain-reflectometry (TDR) as well in many process control applications. Recent research however, is indicating a need to increase the accuracy beyond that available from traditional TDR. The most logical pathway then becomes a transition from TDR based measurements to network analyzer measurements of absolute permittivity that will remove the adverse effects that high surface area soils and conductivity impart onto the measurements of apparent permittivity in traditional TDR applications.This research examines an observed experimental error for the coaxial probe, from which the modern TDR probe originated, which is hypothesized to be due to fringe capacitance. The research provides an experimental and theoretical basis for the cause of the error and provides a technique by which to correct the system to remove this source of error. To test this theory, a Poisson model of a coaxial cell was formulated to calculate the effective theoretical extra length caused by the fringe capacitance which is then used to correct the experimental results such that experimental measurements utilizing differing coaxial cell diameters and probe lengths, upon correction with the Poisson model derived correction factor, all produce the same results thereby lending support and for an augmented measurement technique for measurement of absolute permittivity.
منابع مشابه
Analysis of Coaxial Soil Cell in Reflection and Transmission
Accurate measurement of moisture content is a prime requirement in hydrological, geophysical and biogeochemical research as well as for material characterization and process control. Within these areas, accurate measurements of the surface area and bound water content is becoming increasingly important for providing answers to many fundamental questions ranging from characterization of cotton f...
متن کاملAn Analytical Model for Fringing Capacitance in Double gate Hetero Tunnel FET and Analysis of effect of Traps and Oxide charges on Fringing Capacitance
In this paper fringe capacitance of double hetero gate Tunnel FET has been studied. The physical model for fringe capacitance is derived considering source gate overlap and gate drain non overlap. Inerface trap charge and oxide charges are also introduced under positive bias stress and hot carrier stress and their effect on fringe capacitance is also studied. The fringe capacitance is significa...
متن کاملThe Effect of High-K Gate Dielectrics on Deep Submicrometer CMOS Device and Circuit Performance
The potential impact of high permittivity gate dielectrics on device short channel and circuit performance is studied over a wide range of dielectric permittivities ( gate) using two-dimensional (2-D) device and Monte Carlo simulations. The gate-to-channel capacitance and parasitic fringe capacitances are extracted using a highly accurate three-dimensional (3-D) capacitance extractor. It is obs...
متن کاملTraceability Chain of the Capacitance Unit to Quantum Hall Effect at Inmetro - Four-terminal Coaxial Bridge
− This paper describes the development of a four-terminal coaxial bridge, part of the traceability chain of the capacitance unit to the quantum Hall effect, in construction at Inmetro. This bridge will also be used to calibrate AC resistance and high-value capacitance standards. Here we describe the final construction stages and preliminary measurements of the four-terminal coaxial bridge. We a...
متن کاملCoaxial fiber supercapacitor using all-carbon material electrodes.
We report a coaxial fiber supercapacitor, which consists of carbon microfiber bundles coated with multiwalled carbon nanotubes as a core electrode and carbon nanofiber paper as an outer electrode. The ratio of electrode volumes was determined by a half-cell test of each electrode. The capacitance reached 6.3 mF cm(-1) (86.8 mF cm(-2)) at a core electrode diameter of 230 μm and the measured ener...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2011