Threaded fusion cages for lumbar interbody fusions. An economic comparison with 360 degrees fusions.
نویسنده
چکیده
STUDY DESIGN This study compared the surgical and hospitalization costs, operating times, and blood loss attributable to lumbar interbody fusions at one and two lumbar levels by the use of two device systems: 1) the Ray Threaded Fusion Cage, and 2) an anteroposterior interbody technique with pedicle screw and rod stabilization (360 degrees fusion). The clinical efficacy and complication rate of each method were similar. OBJECTIVES Data were analyzed to compare the newer threaded fusion cage method with the well established 360 degrees technique. SUMMARY OF BACKGROUND DATA Interbody bone grafts are a proven concept to obtain solid spinal fusions. A variety of mechanical means are used to stabilize the graft material during the fusion growth and have been shown to be important in facilitating both the rate and ultimate quality of the fusion. METHODS In a cohort of 50 prospectively selected patients having severe, disabling back pain with discal degeneration, 25 received Ray Threaded Fusion Cages and 25 had anteroposterior interbody fusion procedures using pedicle screws (360 degrees technique) over the period 1991 to 1995. All implants were performed by the same surgeon in the same hospital. All fusions were judged solid by established radiologic criteria. Cost comparisons were made from pertinent medical records using inflation-corrected 1995 U.S. dollars. RESULTS The average combined (surgeon, hospital, anesthesiologist) costs attributed to one-level threaded fusion cage procedures were $25,171, and $41,813 to equivalent 360 degrees procedures, a difference of 40% or $16,642. Costs for two-level cases were $33,113 and $47,320, respectively, differing by 30% or $14,207. The average saving through preferential use of the threaded fusion cage was $14,639 per case, or $365,966 for the 25-patient subgroup. Ten of the 360 degrees fusion cases required later instrumentation removal, adding $8,635 to the costs of each such case, a final difference of $22,889 compared with an equivalent threaded fusion cage case. The actual collections on threaded fusion cage cases were 81% of billed costs and the actual collections on 360 degrees cases were 73% of billed costs. CONCLUSIONS Assuming that the fusion success, clinical outcome, and complication rates are sufficiently similar between these two techniques, the striking improvement in overall surgical and hospitalization costs, surgical time, and blood losses provided by the threaded fusion cage technique can be major decision points in method selection. Further, no threaded fusion cage case having a normal adjacent level preoperatively developed a fusion transition syndrome over a followup period from 3 to 29 months (averaging 24 months) that required a second fusion procedure, and no cage had to be removed because of instrumentation-associated pain, although each of these problems are known to occur in at lease 10% of pedicle screw implants. Ten of the 25 (40%) 360 degrees fusion cases in this study required subsequent instrumentation removal, although no case has required adjacent level surgery for transition syndrome.
منابع مشابه
Minimally invasive techniques for lumbar interbody fusions.
Lumbar spinal fusions have been performed for nearly a century for a variety of spinal conditions and include posterior/posterolateral and anterior lumbar interbody fusions. Traditionally, the ability to achieve adequate exposure to perform these procedures required an open surgical approach; however, the advent of newer techniques and technology, combined with an improved understanding of surg...
متن کاملCT evaluation of lumbar interbody fusion: current concepts.
Operative techniques for fusing an unstable portion of the lumbar spine or immobilizing a painful vertebral motion segment have been in use for many years. Lumbar fusion procedures initially were used to treat patients with infections (tuberculous spondylitis) or misaligned spines (isthmic spondylolisthesis) (1–8). Early techniques involving the use of harvested autogenous bone graft without in...
متن کاملBeta-tricalcium phosphate combined with recombinant human bone morphogenetic protein-2: a substitute for autograft, used for packing interbody fusion cages in the canine lumbar spine.
Beta-tricalcium phosphate (beta-TCP) combined with recombinant human bone morphogenetic protein-2 (BMP-2) was examined as a substitute for autograft for packing into interbody fusion cages in the canine lumbar spine model. Discectomy and interbody cage fusion were performed at three disc spaces in eight dogs. Examination of microradiographs and histological sections of the lumbar spine at 16 we...
متن کاملPosterior lumbar interbody fusion using cages, combined with instrumented posterolateral fusion: a study of 75 cases.
Posterior lumbar interbody fusion (PLIF) with cages can be combined with decompression of the spinal canal and with instrumented posterolateral fusion (IPLF) with pedicle screws, through a single posterior incision. The authors wanted to assess retrospectively the clinical and radiological outcome of PLIF + IPLF performed by the senior author. Between July 1997 and December 2003, 75 patients un...
متن کاملBiomechanical Analysis of Anterior Spinal Instrumentation Constructs for Lumbar Fusions
Corrective surgery for scoliosis with anterior instrumentation can be accomplished with different constructs: single rod, single rod with interbody cages and dual rods. These varying constructs are most often used in the lumbar spine to generate a fusion mass while retaining the natural lordosis of the lumbar region (Sweet, 1999). In a pediatric population or in smaller adults, two screws canno...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Spine
دوره 22 6 شماره
صفحات -
تاریخ انتشار 1997