Microbiological surveillance of hospital ventilation systems in departments at high risk of nosocomial infections.

نویسندگان

  • P Crimi
  • F Argellati
  • G Macrina
  • C Tinteri
  • L Copello
  • D Rebora
  • L Romania
  • R Rizzetto
چکیده

The air in hospital wards with patients at high risk (Surgeries, Intensive Care Units and Bone Marrow Transplant Centers) has been surveyed less than the one in Operating Rooms. Therefore in this study we considered useful to verify the microbic contamination of the air of those wards evaluating the consistency of ventilation systems in relation also to the presence and location of HEPA absolute filters. Seven departments of Genoese San Martino Hospital at high risk of infection were taken into account. In there, environmental investigations have been performed by air samplings and by analyzing bacterial and fungal growth on plates after an incubation period. Almost 60% of all samples taken in wards yielded a positive result and the average values of bacterial and aspergillar charges measured at air flow emission openings decisively exceed the ones considered standard in operating rooms. Still, the average values of airborne bacterial charges were significantly higher in those wards equipped with central filters (p < 0.001), while as far as the aspergillar charge is concerned, no statistically relevant differences were noticed. In wards with ventilation system, the bacterial charge value raises from the emission grids to the middle of the room and to the aspiration grids, while the ward not equipped with a ventilation system presents in the middle of the room an average bacterial charge 2 to 10 times higher than the one in other wards. The average values regarding bacterial and aspergillar charges resulted quite high in all the departments surveyed. Nevertheless, if we take into account ventilation systems equipped with absolute filters HEPA located centrally or peripherally, it can be outlined that the air quality from the point of view of both microbic and aspergillar contamination turns out to be decisively better in systems with peripheral filters. Moreover, a compared analysis of the three Hematology wards allows us to infer that the presence of artificial ventilation systems can lower the bacterial and fungal compared with a ward with natural ventilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

عفونت‌های بیمارستانی و عوامل باکتریایی آنها: بخش مراقبت‌های ویژه نوزادان بیمارستان دانشگاهی قائم (عج) مشهد

Background: Nosocomial infections increase patients' morbidity, mortality and length of hospital stay especially in neonatal intensive care units (NICUs) and have become a matter of major concern. Controlling and preventing nosocomial infections need enough information about epidemiology of these infections. This study aims at estimating the incidence rate and the most frequent bacteria which c...

متن کامل

Clinical, Laboratory and Microbiological Characteristics of Patients with Nosocomial Infections Admitted to Sari Fatemeh Zahra Heart Hospital, 2018-2019

Background and purpose: The term nosocomial infection refers to any type of infection that does not exist at the time of hospital admission and occurs within 48-72 hours after admission or up to 3 days to 6 weeks after discharge, or 30 days after surgery. Nosocomial infections can cause side effects, mortality and reduce quality of life in patients. So, so we decided to study the clinical, labo...

متن کامل

Concurrence of Nosocomial Infections with Microorganisms Spreading in the Air of Hospital Wards

Abstract Background and objectives: A Nosocomial infection is one of the Leading problems causing high mortality among hospitalized patients. This study aimed at confirming the concurrence of Nosocomial infections with microorganisms spreading in the air of hospital wards. Material and Methods: This study was conducted in 2009 at ValieAsr Hospital in Tehran, Iran. The Samples were taken from th...

متن کامل

Operating room ventilation with laminar airflow shows no protective effect on the surgical site infection rate in orthopedic and abdominal surgery.

OBJECTIVE To evaluate whether operating room (OR) ventilation with (vertical) laminar airflow impacts on surgical site infection (SSI) rates. DESIGN Retrospective cohort-study based on routine surveillance data. PATIENTS AND METHODS Sixty-three surgical departments participating voluntarily in the German national nosocomial infections surveillance system "KISS" were included (a total of 99,...

متن کامل

A Risk for Nosocomial Infections: Contamination of Hospital Air Cooling Systems by Acantamoeba spp.

Background and Objectives: In the most Iranian hospitals the internal air is cooled by a system comprising centrifugal blower fan and excelsior filters. Because amoeba can be present in air and dust it may enter into filters of cooling systems. It has been suggested that diffusion of amoebae cyst through air canals may contribute to various types of nosocomial infections. This ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of preventive medicine and hygiene

دوره 47 3  شماره 

صفحات  -

تاریخ انتشار 2006