Whole body MR-PET: a new internal dosimetry method for radiation transport calculation from biokinetic model data

نویسندگان

  • Ana Nunes
  • Francisco Alves
  • Miguel Patrício
چکیده

Institute of Nuclear Sciences Applied to Health (ICNAS), University of Coimbra, Portugal In order to ensure the safe usage of new radiopharmaceuticals in Positron Emission Tomography (PET), it is necessary to quantify the doses delivered to the organs and tissues within the patients’ bodies. A framework that allows estimating the dose delivered by PET has been established by the MIRD Committee [1,2] and ICRP [3]. Although this covers the most important terms and concepts in Internal Radiation Dosimetry (IRD), it does not provide a detailed guide to assist in the development of a full dosimetric study. We discuss the development, implementation, assessment and validation of an accurate method for IRD studies of PET radiotracers. We undertook a systematic review [4,5] of previous PET dosimetry studies to identify the current biodistribution data acquisition and analysis methodologies. The methods reported were compared, particularly in terms of the collection of biokinetic data and the estimation of dose results. As a wide heterogeneity of approaches was found, it is important to assessthe impact of different choices in the internal dose calculation protocol. In particular, we quantify the variation in internal dose with different assumptions regarding organ activity uptake namely, instantaneous uptake vs. different methods to extrapolate to zero activity at time zero. For that purpose, whole-body C-Raclopride PET data have been acquired and the corresponding internal doses estimated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biokinetic modelling of 89-Zr-labelled monoclonal antibodies for dosimetry assessment in humans

Background: Monoclonal antibodies have confirmed their merit as biotherapeutics across a wide spectrum of diseases, including cancer, heart disease, infection, and immune disorders. Materials and Methods: The dynamics of 89Zr-labelled monoclonal antibodies (MAb) after injection into the human body are modelled. This modified biokinetic model can be used for dose assessment not only for 89Zr-lab...

متن کامل

Internal dosimetry of radioiodine using ICRP reference phantoms and updated biokinetic model

The purpose of this study is to estimate internal dose to human body due to administration of I-131 using new biokinetic model of iodine. In this respect, we used international commission on radiological protection (ICRP) adult reference phantoms. Monte Carlo calculations were performed using MCNPX 2.6 code. The average dose to target organ per disintegration inside source organ, namely S facto...

متن کامل

Radiation Dosimetry of Whole-Body Dual-Tracer 18F-FDG and 11C-Acetate PET/CT for Hepatocellular Carcinoma.

UNLABELLED Combined whole-body dual-tracer ((18)F-FDG and (11)C-acetate) PET/CT is increasingly used for staging hepatocellular carcinoma, with only limited studies investigating the radiation dosimetry data of these scans. The aim of the study was to characterize the radiation dosimetry of combined whole-body dual-tracer PET/CT protocols. METHODS Consecutive adult patients with hepatocellula...

متن کامل

Bayesian internal dosimetry calculations using Markov Chain Monte Carlo.

A new numerical method for solving the inverse problem of internal dosimetry is described. The new method uses Markov Chain Monte Carlo and the Metropolis algorithm. Multiple intake amounts, biokinetic types, and times of intake are determined from bioassay data by integrating over the Bayesian posterior distribution. The method appears definitive, but its application requires a large amount of...

متن کامل

Internal dosimetry verification and validation database.

Simulated-data internal dosimetry cases for use in intercomparison exercises or as a software verification and validation tool have been published on the internet (www.lanl.gov/bayesian/software Bayesian software package II). A user may validate their internal dosimetry code or method using this simulated bioassay data. Or, the user may choose to try out the Los Alamos National Laboratory codes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014