SU-E-I-65: Magnetic Resonance Spectroscopy of the Prostate: A Phantom Study of Metabolite Concentrations.

نویسندگان

  • M Hossain
  • T Richardson
  • M K Buyyounouski
  • T Schirmer
  • R Noeske
  • L Chen
  • C Ma
چکیده

PURPOSE Magnetic Resonance Spectroscopy (MRS) of the prostate is not used in radiotherapy departments on a regular basis due to a number of issues. The indication and severity of prostate cancer is related to the presence of choline in the prostate, in particular, the ratio of choline (plus creatine) to citrate. In-vivo data supports this theory only marginally but lacks strong correlation with biopsy data. The situation is further complicated by the lack of precise spatial information in biopsy, variation of magnetic susceptibility, and spatial dependence of MRS data on the distance from the endo-rectal coil. The latter also cause low signal-to-noise ratio (SNR). We intend to understand how the level of metabolite concentrations and spatial dependences determine what is observed in MRS. METHODS A spherical phantom is filled with water solutions containing various amounts of metabolites. It is placed on top of an endo-rectal coil with the balloon filled with per fluorocarbon. MRS data is acquired on a GE 1.5 T MR scanner. The metabolite values, their ratios etc as reported in GE software, FuncTool are studied as functions of metabolite concentrations in the phantom. RESULTS Analysis of the phantom data indicates that the metabolite ratio reported in FuncTool is approximately linearly correlated to the metabolite concentrations used in the phantom to a certain point and then saturates whereas the largest metabolite value is well correlated with its concentration in the phantom. All metabolite values become weaker and SNR lower as we move away from the coil. CONCLUSIONS This work indicates the potential of using metabolite values directly provided their spatial dependences on the distance of the voxels from the endo-rectal coil can be accommodated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

بررسی ارتباط نسبت مجموع کولین و کراتین به سیترات در Magnetic resonance spectroscopy با میزان تهاجم تومور در سرطان پروستات

Background: Prostate cancer is the most common cancer and the second cause of cancer mortality in men. Although histopathological examination is the gold-standard for its diagnosis, tendency toward less invasive methods is growing. The purpose of this study was to evaluate the relationship between choline plus creatine- to-citrate ratio in magnetic resonance spectroscopy (MRS) with the invasion...

متن کامل

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

MRS Shimming: An Important Point Which Should not be Ignored

Introduction: Proton magnetic resonance spectroscopy (MRS) is a well-known device for analyzing the biological fluids metabolically. Obtaining accurate and reliable information via MRS needs a homogeneous magnetic field in order to provide well-defined peaks and uniform water suppression. There are lots of reasons which can disturb the magnetic field homogeneity which can be corrected by a proc...

متن کامل

Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part5  شماره 

صفحات  -

تاریخ انتشار 2012