Methodological considerations for meal-induced thermogenesis: measurement duration and reproducibility.
نویسندگان
چکیده
Meal-induced thermogenesis (MIT) research findings have been highly inconsistent, in part, due to the variety of durations and protocols used to measure MIT. In the present study, we aimed to determine the following: (1) the proportion of a 6 h MIT response completed at 3, 4 and 5 h; (2) the associations between the shorter durations and the 6 h measures; (3) whether shorter durations improved the reproducibility of the measurement. MIT was measured in response to a 2410 kJ mixed composition meal in ten individuals (five males and five females) on two occasions. Energy expenditure was measured continuously for 6 h post-meal using indirect calorimetry, and MIT was calculated as the increase in energy expenditure above the pre-meal RMR. On average, 76, 89 and 96 % of the 6 h MIT response was completed within 3, 4 and 5 h, respectively, and MIT at each of these time points was strongly correlated with the 6 h MIT response (range for correlations, r 0·990-0·998; P< 0·01). The between-day CV for the 6 h measurement was 33 %, but it was significantly lower after 3 h of measurement (CV 26 %; P= 0·02). Despite variability in the total MIT between days, the proportion of MIT that was completed at 3, 4 and 5 h was reproducible (mean CV: 5 %). While 6 h are typically required to measure the complete MIT response, the 3 h measures provide sufficient information about the magnitude of the MIT response and may be applicable for testing individuals on repeated occasions.
منابع مشابه
Title: Methodological considerations for meal-induced thermogenesis: measurement duration and reproducibility Running title: Methodology of meal-induced thermogenesis Key words: meal induced thermogenesis, postprandial, thermic effect of food, reproducibility, energy expenditure Authors:
1 Meal-Induced Thermogenesis (MIT) research findings are highly inconsistent, in part, due to 2 the variety of durations and protocols used to measure MIT. We aimed to determine: 1) the 3 proportion of a 6 h MIT response completed at 3, 4 and 5 h; 2) the associations between the 4 shorter durations and the 6 h measure; 3) whether shorter durations improved the 5 reproducibility of the measureme...
متن کاملP-wave duration and dispersion analysis: methodological considerations.
Methodological Considerations To the Editor: With great interest, we have read the article of Fan and colleagues1 on the effects of biatrial pacing in the prevention of postoperative atrial fibrillation after coronary artery bypass surgery. By measuring P-wave duration from 12-lead surface ECGs and calculating P-wave dispersion, they found that biatrial pacing resulted in a more significant red...
متن کاملP-wave dispersion measurement: Methodological considerations
Well-known difficulties in defining P-wave onset and offset may restrict the accuracy and reproducibility of P-wave dispersion measurements. To achieve greater precision in measuring P-wave dispersion, simultaneous digital recording of all 12 ECG leads and onscreen measurement of P wave characteristics is mandatory to examine atrial fibrillation risk.
متن کاملMeasurement of Cue-Induced Craving in Human Methamphetamine- Dependent Subjects New Methodological Hopes for Reliable Assessment of Treatment Efficacy
Methamphetamine (MA) is a highly addictive psychostimulant drug with crucial impacts on individuals on various levels. Exposure to methamphetamine-associated cues in laboratory can elicit measureable craving and autonomic reactivity in most individuals with methamphetamine dependence and the cue reactivity can model how craving would result in continued drug seeking behaviors and relapse in rea...
متن کاملاعتبار و تکرارپذیری Dual Digital Inclinometer در اندازه گیری زاویه کایفوز پشتی در زنان بالای 45 سال
Objective: Accurate measurement of thoracic kyphosis has high value in the evaluation of patients with spinal kyphosis and in assessing the effectiveness of different treatment methods. Recently, Dual Digital Inclinometer (DDI) has introduced as a non-invasive tool that can measure the kyphosis angle. According to available information there is only one published study regarding the validity an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of nutrition
دوره 110 11 شماره
صفحات -
تاریخ انتشار 2013