Electron beam energy spread measurements using optical klystron radiation

نویسندگان

  • B. Jia
  • J. Li
  • S. Huang
  • Scott C. Schmidler
  • Y. K. Wu
چکیده

B. Jia,* J. Li, S. Huang, Scott C. Schmidler, and Y.K. Wu Department of Physics, Duke University, Durham, North Carolina 27708, USA DFELL, Triangle Universities Nuclear Laboratory, Durham, North Carolina 27708, USA IHIP, School of Physics, Peking University, Beijing 100871, China Department of Statistical Science, Duke University, Durham, North Carolina 27708, USA (Received 28 May 2010; published 4 August 2010)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FEL and optical klystron gain for an electron beam with oscillatory energy distribution∗

If the energy spread of a beam is larger then the Pierce parameter, the FEL gain length increases dramatically and the FEL output gets suppressed. We show that if the energy distribution of such a beam is made oscillatory on a small scale, the gain length can be considerably decreased. Such an oscillatory energy distribution is generated by first modulating the beam energy with a laser via the ...

متن کامل

Optical-klystron Configuration for a High-gain X-ray Free Electron Laser

The amplified spontaneous-emission (ASE) regime of a free electron laser (FEL) can be used to produce coherent soft X-ray radiation in a long undulator (5 5 L -< 10 m) [1-6] . In such a regime, the initial incoherent radiation, with an optical power proportional to the number of electrons, is amplified by the electron beam itself as it traverses the interaction region subject to the combined pe...

متن کامل

Investigation of the Effect of Electron Beam Different Doses on Optical Dissipation in Fiber Optic

Measurement of ionizing radiation in various fields, such as environmental safety, industrial detection processes, radiation protection and medical is very important. Radiation dosimetry plays an important role in determining the amount of energy absorbed and the effects of radiation. Recent optical fiber sensors have been shown to be radiation dosimeters. Our goal here is to investigate the ef...

متن کامل

A Source of Coherent Soft X-ray Radiation Based on High-order Harmonic Generation and Free Electron Lasers∗

We examine a scheme for a Free Electron Laser (FEL) harmonic amplifier seeded by a 30-nm wavelength signal produced using a process of High-order Harmonic Generation (HHG). The seed is first amplified in an optical klystron from 100 kW to 30 MW using a 1 GeV electron beam and then is used for an energy modulation of electrons in the downstream undulator. Subsequently, a 100MW level of radiation...

متن کامل

Simulation of Laser - Electron Beam Interaction in the Optical Klystron of a Free Electron Laser

The particle optics code GPT [1] has been applied to study the single pass electron beam interaction with an external laser field in the undulator system of a free electron laser. In particular, this code has been used to simulate the laser electron beam interaction in an optical klystron. Micro-bunching as a result of the interaction of the electron bunch with an electromagnetic pulse is prese...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010