Determination of Organonitriles Using EnzymemBased Selectivity Mechanisms . 2 . A NitrilasemModif ied Glassy Carbon Microelectrode Sensor for Benzonitrile
نویسندگان
چکیده
A nitrilase-modiiied glassy carbon microelectrode for the detection of benzonitrile in water was developed and analytically characterized. The detection scheme uses Rhodococcus sp. nitrilase to catalyze the hydrolysis of benzonitrile derivatives directly into carboxylic acid and ammonia. The glassy carbon microelectrode surface modillcation was accomplished by attaching a hydrophilic tether to the microelectrode surface and then, using the free terminal amine at its other end, biotinylating with sulfo-NHS-biotin. Afterward, avidin was attached to the spacer arm, followed by the biotinylated nitrilase through avidin-biotin coupling. Benzoic acid, an enzymatic reaction product, is electrochemically reduced at the glassy carbon microelectrode, producing a steady-state reduction current proportional to the concentration of benzonitrile in the sample. In the temperature range of 25 to -20 "C, the biotinylated nitrilase was found to be stable up to 3 times longer than the native enzyme. The activity of the biotinylated nitrilase was optimum over a pH range of 71 1, while that of the native enzyme was optimum only between pH 7 and 9. The nitrile sensor was stable for at least 7 days at 25 "C. It was demonstrated for the detection of benzonitrile at concentrations of 0.1-5 mM in both simple and benzene/chloroform/nitrobemne containing samples.
منابع مشابه
Determination of Organonitriles Using Enzyme-Based Selectivity Mechanisms. 1. An Ammonia Gas Sensing Electrode-Based Sensor for Benzonitrile
published in Aduance ACS Abstracts, Octobar 1, 1993.
متن کاملElectrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode
A sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (MWCNT/GCE), was developed for determination of fenitrothion. Determining the surface area of MWCNT/GCE showed that this surface is three times more active than that of a glassy carbon electrode. The experimental parameters, such as the amount of MWCNTs, pH of the fenitrothion solution, preconcentration potential an...
متن کاملSimultaneous electrochemical determination of Acetaminophen and Codeine based on a MWCNT/MCM48 nanocomposite modified glassy carbon
A novel chemically modified electrode was constructed based on multi-walled carbon nanotubes, MCM48 molecular sieve composite modified glassy carbon electrode .The modified electrode showed that it can be used for simultaneous determination of acetaminophen (ACT) and codeine (COD), simultaneously. The measurements were carried out by the application of differential pulse voltammetry (DPV), cycl...
متن کاملStudy and Electrochemical Determination of Tyrosine at Graphene Nanosheets Composite Film Modified Glassy Carbon Electrode
A graphene nanosheets (GNS) film coated glassy carbon electrode (GCE) was fabricated for sensitive determination of tyrosine (Tyr). The GNS-based sensor was characterized by scanning electron microscope and electrochemical impedance spectroscopy. The voltammetric techniques were employed to study electro-oxidation of Tyr. The results revealed that the modified electrode showed an electrocatalyt...
متن کاملA Certain Electrochemical Nanosensor Based on Functionalized Multi-Walled Carbon Nanotube for Determination of Cysteine in the Presence of Paracetamol
The modified glassy carbon electrode (GCE) was prepared with 6-amino-4-(3,4-dihydroxyphenyl)-3-methyl-1,4-dihydropyrano[2,3-c]pyrazole-5-carbonitrile (pyrazole derivative (AMPC)) and functionalized multi-walled carbon nanotubes. In this research, electrocatalytic activity of nanocomposite (AMPC/MWCNTs) has been studied by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2001