The comparison of the lengths and diameters of main bronchi measured from two-dimensional and three-dimensional images in the same patients

نویسندگان

  • Jeong Woo Lee
  • Ji-Seon Son
  • Jin-Wook Choi
  • Young-Jin Han
  • Jun-Rae Lee
چکیده

BACKGROUND Recently, multi-planar reconstruction of the three-dimensional (3D) spiral chest CT scan has demonstrated superiority in the evaluation of the tracheobronchial tree. The goal of this study was to measure the lengths of the right and left main bronchi and their anteroposterior (AP) and transverse (TR) diameters using the 3D and two-dimensional (2D) images in the same adult respectively, and to evaluate the degree of correlation between them. METHODS We measured the lengths of the right and left main bronchi from the carina to the first of their branches and the AP and TR diameters at the mid-portion of the right main bronchus and 2 cm below the carina in the left main bronchus. We determined the size of the left-sided double-lumen tube (DLT) based on the measured AP diameter of the left main bronchus from the 3D and 2D images, respectively. RESULTS There was moderate correlation between the lengths of both main bronchi obtained from the 3D images and the 2D images, and between the AP diameter of the left main bronchus obtained from the 3D images and the 2D images. Same sized DLTs were estimated in 69% of the men and 34% of the women. CONCLUSIONS The lengths of the right and left main bronchi and their AP and TR diameters obtained from 3D images were not strongly correlated with those from 2D images. Therefore, a further study is needed to verify the superiority of 3D images in selecting the appropriate size of left-sided DLT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and precision of measurements obtained from conventional cephalograms and CBCT scan in orthodontics linear diagnostic measurements

Background and Purpose:  Due to the important role of imaging in the diagnosis and treatment plan in orthodontics, CBCT (Cone Beam Computed Tomography) images because of their three-dimensional nature, can minimize the disadvantages of two-dimensional images such as magnification, distortion, or superimposition. The purpose of this study was to evaluate the accuracy of conventional cephalograms...

متن کامل

مقایسه تصاویر دو بعدی و سه بعدی در یادگیری درس علوم اعصاب

Background and Purpose: Using images is a requirement of medical education and evaluation of effect of type of image on learner could be helpful for medical education. The purpose of the present study is comparison of two dimensional and three dimensional images in neuroscience learning. Method: In present case control study, equal number of two dimensional and three dimensional images of neur...

متن کامل

Possibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs

Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...

متن کامل

Comparative Study between Hologram Technology and Augmented Reality

The great development witnessed by our current age has led to the emergence of many diverse modern technologies, one of these advanced technologies is Hologram technology and Augmented reality technology, These two technologies are somewhat similar to somewhat, as it can be said that they perform almost the same purpose, and at the same time, Hologram technology differs from augmented reality i...

متن کامل

A comparison of the accuracy and dimensional stability between two silicon impression materials (Speedex and Irasil)

A comparison of the accuracy and dimensional stability between two silicon impression materials (Speedex and Irasil) Dr. M. Sabouhi* - Dr. M. Dakhilalian** - Dr. N. Nehchiri*** *- Assistant Professor of Fixed Prosthodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Sciences. **- Member of Fixed Prosthodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Scienc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 66  شماره 

صفحات  -

تاریخ انتشار 2014