Nocturnal oxygen saturation profiles of healthy term infants
نویسندگان
چکیده
OBJECTIVE Pulse oximetry is used extensively in hospital and home settings to measure arterial oxygen saturation (SpO2). Interpretation of the trend and range of SpO2 values observed in infants is currently limited by a lack of reference ranges using current devices, and may be augmented by development of cumulative frequency (CF) reference-curves. This study aims to provide reference oxygen saturation values from a prospective longitudinal cohort of healthy infants. DESIGN Prospective longitudinal cohort study. SETTING Sleep-laboratory. PATIENTS 34 healthy term infants were enrolled, and studied at 2 weeks, 3, 6, 12 and 24 months of age (N=30, 25, 27, 26, 20, respectively). INTERVENTIONS Full overnight polysomnography, including 2 s averaging pulse oximetry (Masimo Radical). MAIN OUTCOME MEASUREMENTS Summary SpO2 statistics (mean, median, 5th and 10th percentiles) and SpO2 CF plots were calculated for each recording. CF reference-curves were then generated for each study age. Analyses were repeated with sleep-state stratifications and inclusion of manual artefact removal. RESULTS Median nocturnal SpO2 values ranged between 98% and 99% over the first 2 years of life and the CF reference-curves shift right by 1% between 2 weeks and 3 months. CF reference-curves did not change with manual artefact removal during sleep and did not vary between rapid eye movement (REM) and non-REM sleep. Manual artefact removal did significantly change summary statistics and CF reference-curves during wake. CONCLUSIONS SpO2 CF curves provide an intuitive visual tool for evaluating whether an individual's nocturnal SpO2 distribution falls within the range of healthy age-matched infants, thereby complementing summary statistics in the interpretation of extended oximetry recordings in infants.
منابع مشابه
Reference values of nocturnal oxygenation for use in outpatient oxygen weaning protocols in premature infants.
OBJECTIVE To define reference ranges for oxygen saturation (SpO(2) ) values in healthy full-term infants in the first days of life and in preterm infants off supplemental oxygen as they approach neonatal intensive care unit (NICU) discharge. METHODS From April 2009 to March 2010, we enrolled convenience samples of full-term infants from the newborn nursery and former preterm infants who did n...
متن کاملRespiratory instability of term and near-term healthy newborn infants in car safety seats.
OBJECTIVE Premature infants who are discharged from intensive care nurseries are known to be at increased risk for apnea, bradycardia, and oxygen desaturation while in the upright position. These small infants also do not fit securely in standard infant car seats. Because of these problems, the American Academy of Pediatrics recommends a period of observation in a car seat for all infants who a...
متن کاملMeasurement of brain tissue oxygen saturation in term infants using a new portable near-infrared spectroscopy device.
BACKGROUND A small oximeter with the probe attached to the examiner's finger has been developed. The aim of this study was to determine the feasibility of measuring regional oxygenation of the brain tissue using this device in healthy term infants immediately after birth. METHODS We conducted a prospective observational study. Using a new near-infrared spectroscopy (NIRS) device, we measured ...
متن کاملArterial oxygen saturation profiles in healthy preterm infants.
AIM To construct a reference range of SpO2 values in healthy preterm infants using a simple data logging device. METHODS Thirty three healthy preterm infants were monitored for a continuous period of 4 hours at rest using an Ohmeda Biox 3700 E Pulse Oximeter and an electronic data logger (Rustrack Ranger). Stored data were downloaded and saved as individual files on a personal computer. RES...
متن کاملOxygen saturation in healthy infants immediately after birth.
OBJECTIVE Because the optimal concentration of oxygen (FiO2) required for stabilization of the newly born infant has not been established, the FiO2 is commonly adjusted according to the infant's oxygen saturation (SpO2). We aimed to determine the range of pre-ductal SpO2 in the first minutes of life in healthy newborn infants. STUDY DESIGN We applied an oximetry sensor to the infant's right p...
متن کامل