Development and validation of an automated algorithm to evaluate the abundance of bubbles in small bowel capsule endoscopy

نویسندگان

  • Olivia Pietri
  • Gada Rezgui
  • Aymeric Histace
  • Marine Camus
  • Isabelle Nion-Larmurier
  • Cynthia Li
  • Aymeric Becq
  • Einas Abou Ali
  • Olivier Romain
  • Ulriikka Chaput
  • Philippe Marteau
  • Christian Florent
  • Xavier Dray
چکیده

Background and study aims  Bubbles can impair visualization of the small bowel (SB) mucosa during capsule endoscopy (CE). We aimed to develop and validate a computed algorithm that would allow evaluation of the abundance of bubbles in SB-CE still frames. Patients and methods  Two sets of 200 SB-CE normal still frames were created. Two experienced SB-CE readers analyzed both sets of images twice, in a random order. Each still frame was categorized as presenting with < 10 % or ≥ 10 % of bubbles. Reproducibility (κ), sensitivity (Se), specificity (Sp), receiver operating characteristic curve, and calculation time were measured for different algorithms (Grey-level of co-occurrence matrix [GLCM], fractal dimension, Hough transform, and speeded-up robust features [SURF]) using the experts' analysis as reference. Algorithms with highest reproducibility, Se and Sp were then selected for a validation step on the second set of frames. Criteria for validation were κ = 1, Se ≥ 90 %, Sp ≥ 85 %, and a calculation time < 1 second. Results Both SURF and GLCM algorithms had high operating points (Se and Sp over 90 %) and a perfect reproducibility (κ = 1). The validation step showed the GLCM detector strategy had the best diagnostic performances, with a Se of 95.79 %, a Sp of 95.19 %, and a calculation time of 0.037 seconds per frame. Conclusion A computed algorithm based on a GLCM detector strategy had high diagnostic performance allowing assessment of the abundance of bubbles in SB-CE still frames. This algorithm could be of interest for clinical use (quality reporting) and for research purposes (objective comparison tool of different preparations).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnosis and Treatment of Small Bowel Cancers Using Radioactive Gold Nanoparticles and Wireless Fluorescence Capsule Endoscopy

Background: Therapeutic and diagnosis properties of radioactive gold nanoparticle (198-AuNPs) cause them to be suitable for detection and treatment of tumors.Objective: Electrical and optical properties of PEG-198AuNPs were examined in this paper. Polyethylene Glycol (PEG)-198 AuNPs can be used for treatment and diagnosis of small intestine tumors.Methods: Wireless fluorescence capsule endoscop...

متن کامل

Challenges and Future of Wireless Capsule Endoscopy.

In 2015, capsule endoscopy was introduced as the main investigation method for small bowel mucosal diseases, and its role in colonic diseases has been gradually revealed. Future challenges for capsule endoscopy, besides improvements of image quality and visualization of each part of the small bowel and colonic mucosa, include the development of gastric capsules, the capacity to perform histolog...

متن کامل

Video capsule endoscopy in small-bowel malignancy: a multicenter Belgian study.

BACKGROUND AND STUDY AIMS Early diagnosis of small-bowel tumors is crucial for therapy. Video capsule endoscopy has improved the diagnosis of small-bowel diseases, but data concerning the role of this technique in detecting small-bowel malignancy are scarce. The aim of this paper was to review all capsule endoscopy findings at Belgian hospitals, in order to evaluate the diagnostic yield of caps...

متن کامل

Optimal Bowel Preparation for Video Capsule Endoscopy

During video capsule endoscopy (VCE), several factors, such as air bubbles, food material in the small bowel, and delayed gastric and small bowel transit time, influence diagnostic yield, small bowel visualization quality, and cecal completion rate. Therefore, bowel preparation before VCE is as essential as bowel preparation before colonoscopy. To date, there have been many comparative studies,...

متن کامل

A new memetic algorithm for mitigating tandem automated guided vehicle system partitioning problem

Automated Guided Vehicle System (AGVS) provides the flexibility and automation demanded by Flexible Manufacturing System (FMS). However, with the growing concern on responsible management of resource use, it is crucial to manage these vehicles in an efficient way in order reduces travel time and controls conflicts and congestions. This paper presents the development process of a new Memetic Alg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2018