Adaptation of Prostatic-Group-Label Homogeneous Immunoassay to reagent-strip format.
نویسندگان
چکیده
The Prostatic-Group-Label Immunoassay (PGLIA) technique has been incorporated into a reagent-strip format. We report use of flavin N6-(N'-2,4-dinitrophenyl-6-aminohexyl)adenine dinucleotide (DNP-FAD) as the prosthetic group derivative and 6-N-(2,4-dinitrophenyl)aminohexanoic acid (DNP-caproate) as the competing ligand. DNP-FAD not bound by antibody combines with glucose oxidase apoenzyme, which then reacts with glucose and oxygen, and gives color through a peroxidase-linked system. The rate of color generation is thus a function of the DNP-caproate concentration. PGLIA reagent strips are prepared by sequential impregnations of filter paper with an acetone solution of indicator (3,3',5,5'-tetramethylbenzidine); an aqueous solution containing glucose oxidase apoenzyme, the rest of the color generation system, stabilizers, and antibody to DNP; and a solution of DNP-FAD in n-propanol. This preparation permits effective antibody binding, and prevents premature interaction of immunoassay components. A quantitative color response to concentrations of DNP-caproate in the range of 1 to 8 mumol/L was demonstrated with these reagent strips. Prototype PGLIA reagent strips for theophylline and phenytoin have been successfully developed by substituting the appropriate FAD derivative and antibody for the corresponding reagents in the DNP model system.
منابع مشابه
A dry-reagent strip for quantifying carbamazepine evaluated.
We examined a new colorimetric homogeneous immunoassay for carbamazepine based on the apoenzyme reactivation immunoassay system (ARIS) principle. The test, in dry-reagent strip format, is to be used with the Ames Seralyzer reflectance photometer. Within-run CVs (n = 20) were 3.0%, 2.7%, and 2.8% at 3.0, 6.1, and 12.1 mg/L; between-run CVs (n = 15, in 15 days) were 4.1%, 2.7%, and 1.9% at 6.0, 9...
متن کاملHomogeneous fluorescent immunoassay with dry reagents.
We described an assay for theophylline in serum in which the reagents for the substrate-labeled fluorescent immunoassay procedure are dry reagents in a paper matrix. This assay format is both rapid and convenient. In one such paper strip assay, the competing drug conjugate is present in the diluting buffer (dilution-into-conjugate strip assay); in another, all necessary assay reagents are conta...
متن کاملDiagnosis of schistosomiasis by reagent strip test for detection of circulating cathodic antigen.
A newly developed reagent strip assay for the diagnosis of schistosomiasis based on parasite antigen detection in urine of infected individuals was evaluated. The test uses the principle of lateral flow through a nitrocellulose strip of the sample mixed with a colloidal carbon conjugate of a monoclonal antibody specific for Schistosoma circulating cathodic antigen (CCA). The strip assay to diag...
متن کاملA Multi-step Immunoassay Using Dry, Patterned Reagents in a Two-dimensional Paper Network Format
Here we demonstrate a multistep immunoassay using the controlled release of reagents patterned on a single porous membrane. Reagents are patterned, dried, and stored on-device for later rehydration, which removes the need for a cold chain and reduces user steps through the on-strip combination of signal enhancement reagents. The limit of detection for the malaria antigen Plasmodium falciparum h...
متن کاملSimple adaptation of a radioimmunoassay kit for serum cortisol used to measure salivary cortisol.
Drug immunoassays with use of reagent strips have been introduced by the Ames Co. for theophylline and phenytoin assays. Their phenobarbital assay is based on the ais (Apoenzyme Reactivation Immunoassay System) principle. Thirty microlitres of diluted serum is applied to the reagent pad and the strip is read in the Seralyzer reflectance photometer after 85 s. Fifty-three serum samples assayed b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 27 9 شماره
صفحات -
تاریخ انتشار 1981