Direct, simultaneous measurement of chloramphenicol and its monosuccinate ester in micro-samples of plasma by radial-compression liquid chromatography.

نویسندگان

  • A el-Yazigi
  • A Yusuf
  • A Al-Humaidan
چکیده

A simple method of simultaneous analysis for chloramphenicol and chloramphenicol succinate in 10-microL samples of plasma is described. We injected the plasma samples directly into a radial-compression liquid chromatograph equipped with a precolumn module and a C18 insert. A mixture of acetic acid solution (pH 3)/acetonitrile (75/25, by vol) was used as mobile phase, at a flow rate of 4 mL/min. We separated the compounds in a 10-micron (particle size) C18 cartridge with a radial compression separation system and detected them in the effluent at 280 nm. The peak height for both compounds was linearly (r greater than 0.9993) related to concentration over the range investigated, 1-50 mg/L. We also performed the analysis with use of an internal standard (methylprednisolone) and obtained equally good results (r greater than 0.9995). We observed no interference from other antibiotics or drugs in the assay, and the inter- and intra-run precision at different concentrations was good (CV, 0 to 5.6%). We analyzed microsamples of plasma from an infant treated for meningitis with chloramphenicol sodium succinate intravenously. Total analysis time for each sample was less than 8 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitive Simultaneous Measurement of Metformin and Linagliptin in Plasma Samples by Couple of Nano Graphene Oxide-based Dispersive Solid Phase Extraction Method and Liquid Chromatography

A simple, rapid, and ultra sensitive dispersive solid phase extraction based on nano graphene oxide was developed for simultaneous measurement of trace amounts of metformin (MET) and linagliptin (LIN) in plasma samples by HPLC-UV-Vis. Affecting factors on the extraction of these drugs, including adsorbent weight, extraction time, organic solvent type, desorption situations, and composition of s...

متن کامل

Sensitive Simultaneous Measurement of Metformin and Linagliptin in Plasma Samples by Couple of Nano Graphene Oxide-based Dispersive Solid Phase Extraction Method and Liquid Chromatography

A simple, rapid, and ultra sensitive dispersive solid phase extraction based on nano graphene oxide was developed for simultaneous measurement of trace amounts of metformin (MET) and linagliptin (LIN) in plasma samples by HPLC-UV-Vis. Affecting factors on the extraction of these drugs, including adsorbent weight, extraction time, organic solvent type, desorption situations, and composition of s...

متن کامل

Determination of Amphetamine and Methamphetamine by Dispersive Liquid Phase Micro-extraction: A Novel Experimental Approach

Background: A syringe to syringe dispersive liquid phase micro-extraction-floating organic drop was applied and used for the simultaneous extraction and pre-concentration of trace amounts of amphetamine (AMP) and methamphetamine (MAMP) in urine samples. The extracted analytes were determined by high performance liquid chromatography along with diode array detection. Materials & Methods: In thi...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 33 10  شماره 

صفحات  -

تاریخ انتشار 1987