Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700

نویسندگان

  • Akira Kobayashi
  • Hideaki Yokogawa
  • Natsuko Mori
  • Kazuhisa Sugiyama
چکیده

BACKGROUND To report the feasibility of intraoperative spectral domain optical coherence tomography (OCT) using the RESCAN 700 for the visualization and evaluation of precut Descemet's stripping automated endothelial keratoplasty (DSAEK) and prestripped Descemet's membrane endothelial keratoplasty (DMEK) donor tissue. METHODS Precut DSAEK (n = 11), prestripped DMEK (n = 4) preserved in a viewing chamber were examined by intraoperative OCT. Wholly intact donor corneas for penetrating keratoplasty (PK) (n = 8) were also examined as controls. The obtained images were analyzed qualitatively for characteristics of each type of donor. RESULTS For each type of donor, characteristic images were consistently obtained by intraoperative OCT in both the front and back views through the viewing chamber. In wholly intact donors for PK, appearance of normal corneal curvature and stromal texture with high reflectivity of epithelium and endothelium cell layers were clearly visualized. In precut DSAEK donors, precut lines were characteristically visualized in addition to the intact donor cornea images. In prestripped DMEK donors, identical OCT images to the intact donor cornea were noted when observed from the anterior surface. However, peripheral partial detachments of Descemet's membrane were characteristically observed in all prestripped DMEK donors when viewed from the back of the viewing chamber. CONCLUSION Rapid visualization and rough evaluation of donor tissues for PK, precut DSAEK and prestripped DMEK donor corneas by intraoperative OCT was consistently possible through the viewing chamber. Therefore, this device may be used as an alternative of AS-OCT when the eyebank does not have their own AS-OCT. Although the peripheral detachment in DMEK donors are quite common and clinically non-problematic in DMEK donor quality and subsequent DMEK surgeries, it may be useful to distinguish between wholly intact PK donors and prestripped DMEK donors, enabling to prevent mix-ups of donors, especially when several different types of keratoplasties are scheduled in a same day in one operating theater.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Descemet Membrane Endothelial Keratoplasty: Intraoperative and Postoperative Imaging Spectral-Domain Optical Coherence Tomography

We describe a case report of using the same handheld spectral-domain anterior segment optical coherence tomography (ASOCT) for rapid intraoperative and postoperative imaging in a case of Descemet membrane endothelial keratoplasty (DMEK). A 67-year-old woman, with Fuchs dystrophy and corneal decompensation, underwent DMEK with intraoperative ASOCT imaging using the handheld Envisu spectral domai...

متن کامل

Corneal donor tissue preparation for Descemet's membrane endothelial keratoplasty.

Descemet's Membrane Endothelial Keratoplasty (DMEK) is a form of corneal transplantation in which only a single cell layer, the corneal endothelium, along with its basement membrane (Descemet's membrane) is introduced onto the recipient's posterior stroma(3). Unlike Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK), where additional donor stroma is introduced, no unnatural stroma-...

متن کامل

Intraoperative Optical Coherence Tomography Using the RESCAN 700: Preliminary Results in Collagen Crosslinking

PURPOSE To compare the penetration of riboflavin using a microscope-integrated real time spectral domain optical coherence tomography (ZEISS OPMI LUMERA 700 and ZEISS RESCAN 700) in keratoconus patients undergoing accelerated collagen crosslinking (ACXL) between epithelium on (epi-on) and epithelium off (epi-off). METHODS Intraoperative images were obtained during each of the procedures. Seve...

متن کامل

Corneal topographic analysis by 3-dimensional anterior segment optical coherence tomography after endothelial keratoplasty.

PURPOSE To investigate the characteristics of the corneal topography with three-dimensional (3-D) anterior segment optical coherence tomography (AS-OCT) following Descemet's stripping automated endothelial keratoplasty (DSAEK). METHODS Thirty-four eyes of 33 patients following DSAEK were studied. In addition to conventional topographic maps, the elevation map of the intrastromal interface and...

متن کامل

Experimental Visualization of Labyrinthine Structure with Optical Coherence Tomography

Introduction:Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may be used for the visualization of tissues. In this experimental study we aimed to evaluate inner ear anatomy in well-prepared human labyrinthine bones.Materials and Methods:Thr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016