Acute effects of embolizing systemic-to-pulmonary arterial collaterals on blood flow in patients with superior cavopulmonary connections: a pilot study.

نویسندگان

  • Yoav Dori
  • Andrew C Glatz
  • Brian D Hanna
  • Matthew J Gillespie
  • Matthew A Harris
  • Marc S Keller
  • Mark A Fogel
  • Jonathan J Rome
  • Kevin K Whitehead
چکیده

BACKGROUND The significance and optimal treatment of systemic-to-pulmonary arterial collateral (SPC) vessels in single ventricle patients are poorly understood. The acute efficacy of SPC embolization has not been demonstrated in a quantifiable fashion. We sought to assess the acute efficacy of SPC embolization on blood flow as quantified by phase contrast magnetic resonance imaging and hypothesized that embolization acutely decreases SPC flow and increases systemic blood flow (Q(S)). METHODS AND RESULTS Six superior cavopulmonary connection patients underwent SPC flow quantification by phase contrast magnetic resonance imaging, including quantification of superior and inferior caval, total pulmonary artery, total pulmonary vein, ascending and descending aortic flows (Q(SVC), Q(IVC), Q(PA), Q(PV), Q(Ao), and Q(Dao), respectively), both immediately before and after cardiac catheterization with coil and particle embolization of angiographically evident SPC vessels. All studies were performed under a single anesthetic. After embolization, we found a significant decrease in SPC flow of 0.9 (range, 0.6-1.3) L/(min·m(2)) (P=0.03); a median reduction of 47% (range, 32-60). There was a significant decrease in the median Q(P):Q(S) from 1.3 before to 0.8 after embolization (P=0.03), and an increase in Q(S) from a median of 3.4 to 4.4 L/(min·m(2)) (P<0.05), and Q(SVC) from a median of 1.7 to 2.3 L/(min·m(2)) (P=0.03). CONCLUSIONS We report on the acute efficacy of SPC embolization, demonstrating a significant decrease in SPC flow and Q(P):Q(S) and increase in Q(SVC) and Q(S). Further studies are needed to assess the durability of the procedure and the effect on Fontan and longer-term outcomes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aortopulmonary collaterals after bidirectional cavopulmonary connection or Fontan completion: quantification with MRI.

BACKGROUND Aortopulmonary collaterals (APCs) have been associated with increased morbidity after the Fontan operation. We aimed to quantify APC flow after bidirectional cavopulmonary connections and Fontan completions, using phase-contrast MRI, and to identify risk factors for the development of APCs. METHODS AND RESULTS APC blood flow was quantifiable in 24 of 36 retrospectively analyzed MRI...

متن کامل

Pulmonary/systemic flow ratio in children after cavopulmonary anastomosis.

OBJECTIVES This study attempted to provide a formula for calculation of the pulmonary/systemic flow ratio in children after bidirectional cavopulmonary anastomosis. BACKGROUND With the bidirectional cavopulmonary anastomosis, only the superior vena cava blood is oxygenated by the lungs. The inferior vena cava flow recirculates into the systemic circulation. The ratio of these flows will deter...

متن کامل

THE EFFECTS OF CAPTOPRIL ON PULMONARY AND SYS TEMIC ARTERIAL PRESSURES IN HIGHALTITUDE PULMONARY HYPERTENSION

The purpose of this investigation was to assess the effect of captopril on both systemic (P.a) and pulmonary arterial pressures (PPA) in patients with high-altitude pulmonary hypertension (HAPH). Seventeen patients (mean age 44±6.8 years) with HAPH and mild to moderate systemic arterial hypertension were included in the study. All patients underwent right heart catheterization with measurem...

متن کامل

Accuracy of conventional oximetry for flow estimation in patients with superior cavopulmonary connection: a comparison with phase-contrast cardiac MRI.

BACKGROUND Cardiac catheterization is routinely used as a diagnostic tool in single ventricle patients with superior cavopulmonary connection. This physiology presents inherent challenges in applying the Fick principle to estimate flow. We sought to quantitatively define the error in oximetry-derived flow parameters using phase-contrast cardiac MRI (CMR) as a reference. METHODS AND RESULTS Th...

متن کامل

Theoretical optimization of pulmonary-to-systemic flow ratio after a bidirectional cavopulmonary anastomosis.

A univentricle with parallel pulmonary and systemic circulations is inherently inefficient because mixing of pulmonary and systemic venous return occurs. Thus a cavopulmonary anastomosis is used as a staged palliative procedure to reduce volume overload in patients with cyanotic congenital heart disease. On the basis of oxygen uptake and consumption, an equation was derived that related cardiac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 6 1  شماره 

صفحات  -

تاریخ انتشار 2013