Post dural puncture headache following intrathecal drug delivery system placement.

نویسندگان

  • Stephanie A Neuman
  • Jason S Eldrige
  • Wenchun Qu
  • Eric D Freeman
  • Bryan C Hoelzer
چکیده

BACKGROUND Placement of an intrathecal drug delivery system (IDDS) may provide substantial benefit to certain patients. However, placement of these devices is not without complications, and minimal data exist describing the rates of these complications. Specifically, there is a paucity of data describing the incidence of post dural puncture headache (PDPH) following IDDS placement. OBJECTIVES The aim of this study was to identify the incidence and treatment course of PDPH following placement of an IDDS in a retrospective review. STUDY DESIGN Retrospective assessment of medical records. SETTING Department of Pain Medicine and Anesthesiology, Mayo Clinic, Rochester, MN. METHODS Following IRB approval, 319 IDDS surgical reports in 285 patients were identified retrospectively over a 20 year study time period. We report demographic information, number of dural punctures, techniques for sealing dural leak, details, and treatment course of PDPH in this population. RESULTS Symptoms of PDPH were recognized in 73 individual cases (23% of total procedural volume). Younger patient age was the only statistically significant characteristic in predicting development of a PDPH. There were no statistically significant differences found in regards to other risk factors for PDPH development or treatment strategy employed. Seventy-nine percent of PDPH patients were successfully managed with conservative non-interventional therapies (bedrest, IV fluids, analgesics, antiemetics), while 21% required progression to epidural blood or fibrin glue patch procedures for full resolution of symptoms. LIMITATIONS Limitations include the retrospective design of the study as well as the potential for undocumented or improperly documented surgical techniques and/or events.  CONCLUSION Though the development of PDPH after IDDS implantation was found to be fairly common (23% incidence), the majority of these patients had self-limited symptoms that resolved with conservative medical management. Epidural blood patch or application of epidural fibrin glue was therapeutically successful for the remainder of PDPH patients who were refractory to conservative measures. 

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subdural Hematoma and Postdural Puncture Headache from Intrathecal Pump Placement Resolved with Lumbar Epidural Blood Patch

Intrathecal drug delivery systems are commonly used in the management of chronic pain, cancer pain and neuromuscular disorders with muscle spasticity. The complications associated with intrathecal pump placement include persistent cerebrospinal fluid (CSF) leak, hygroma, meningitis, and granuloma formation. A severe persistent CSF leak may cause postdural puncture headache along with acute intr...

متن کامل

Insertion of an intrathecal catheter following accidental dural puncture: a meta-analysis.

BACKGROUND Inserting an intrathecal catheter after accidental dural puncture in parturients to prevent postdural puncture headache is becoming increasingly popular. We aimed to identify relevant published articles investigating this intervention and subject data to a meta-analysis. METHODS A systematic literature search was performed, paralleled by a hand search of abstract publications. Stud...

متن کامل

Nonpharmacologic Neuraxial Interventions for Prophylaxis of Postdural Puncture Headache in the Obstetric Patient.

Postdural puncture headache due to accidental dural puncture during epidural catheter placement is a source of morbidity for new mothers. It can interfere with maternal-newborn bonding and increase the length of hospitalization. This evidence-based article examined the question: For obstetric patients experiencing an accidental dural puncture during epidural placement, which nonpharmacologic pr...

متن کامل

Decrease in the incidence of post-dural puncture headache: maintaining CSF volume.

The incidence of epidural needle-induced post-dural puncture headache (PDPH) in parturients following dural puncture with a large bore (18-gauge) needle has been reported to range 76-85%. We describe seven cases in which the performance of epidural anesthesia in parturients was complicated by an unintentional dural puncture with an 18-gauge epidural needle. In all seven cases, the unintentional...

متن کامل

Persistent Spinal Headache After Removal of Intrathecal Drug Delivery System: A Case Report and Review of Literature

INTRODUCTION To report and discuss the spinal headache following insertion and removal of intrathecal drug delivery system in patients with chronic pain disorders. CASE PRESENTATION Intrathecal drug delivery system (IDDS) was initially used for the management of chronic malignant pain; it has since been used to manage pain from other nonmalignant conditions as well. Spinal headache is one of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pain physician

دوره 16 2  شماره 

صفحات  -

تاریخ انتشار 2013