Development of a routine method for the determination of trace metals in whole blood by magnetic sector inductively coupled plasma mass spectrometry with particular relevance to patients with total hip and knee arthroplasty.

نویسندگان

  • C P Case
  • L Ellis
  • J C Turner
  • B Fairman
چکیده

BACKGROUND Joint-replacement surgery has revolutionized the treatment of osteoarthritis and is still the most effective therapy. A recent clinical trend reintroducing metal-on-metal bearing surfaces has in turn stimulated a requirement for accurate measurement of the concentrations of relevant metals in both pre- and postoperative patients. Thus, there is a need for cost-effective, multielement methods for trace metal analysis in whole blood to monitor possible increases in wear metal concentrations. METHODS A method was developed to allow routine analysis of whole blood samples for molybdenum, cobalt, chromium, and nickel. Sample preparation consisted of a simple 1:10 dilution of whole blood with a solution of 10 mL/L Triton X-100, 0.0002 mol/L EDTA, and 0.01 mol/L ammonium hydroxide. Final determination was performed by a double-focusing magnetic sector inductively coupled plasma mass spectrometer operated in medium-resolution mode (resolution, 3400). Online addition of rhodium was used for internal standardization. RESULTS Detection limits in whole blood were 0.06 microg/L for chromium, cobalt, and molybdenum and 0.30 microg/L for nickel. Base concentrations of 0.22, 0.17, 0.62, and 0.99 microg/L for chromium, cobalt, molybdenum, and nickel, respectively, in whole blood have been found. Polyatomic interferences on all four elements have been shown to be resolved from the analyte masses by use of a resolution of >3000. CONCLUSIONS The simple, rapid method of sample preparation is effective in minimizing potential contamination and enables 60 samples (run time, 8 h) to be analyzed before cleaning the instrument is necessary. A resolution >3000 was sufficient to separate polyatomic interferences from the masses of interest. The method was used to analyze a large number of blood samples taken from primary patients awaiting total hip arthroplasty. The method is sensitive enough to provide base concentrations for chromium, cobalt, and molybdenum in whole blood. The results for nickel were compromised by high signals for blank samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry

In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...

متن کامل

Trace Metals and Major Elements in Sediments of the Northern Persian Gulf

The concentrations of sixteen elements and organic carbon were determined in 78 marine sediment samples collected from the Iranian coastal waters of the Persian Gulf. Nine transects perpendicular to the coastline were sampled. Sixteen elements, including As, Ba, Cd, Co, Cu, Mn, Ni, Pb, Zn (trace metals) and Ca, Fe, Mg, Na, P, S, Si (major metals), were determined by Inductively Coupled Plasma M...

متن کامل

Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression

A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...

متن کامل

Tranexamic Acid in Total Joint Arthroplasty: Efficacy and Safety

  Despite improvements in surgical and anesthetic techniques, total joint arthroplasty (TJA) is still associated with substantial blood loss and postoperative anemia (1). A considerable portion of patients with postoperative anemia require blood transfusion, which has been shown to negatively affect the outcome of TJA and predisposes patients to development of surgical site infection and peripr...

متن کامل

Microwave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes

Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 2  شماره 

صفحات  -

تاریخ انتشار 2001