A Stripline-like Coil Element Structure for High Field Phased Array Coils and its Application for a 8-channel 9.4T Small Animal Transceive Array

نویسندگان

  • Y. Li
  • E. Weber
  • B. Li
  • F. Liu
  • J. Schneider
  • S. Ohrel
  • S. Junge
  • P. Ullmann
  • M. Wick
  • S. Crozier
چکیده

Introduction Ultra-high magnetic field strength, as widely utilised in small animal MRI systems, has advantages of being able to enhance signal-to-noise ratio (SNR) and gain high spectral resolution [1]. However, the homogeneity of B1 field worsens along with the move to higher RF-frequencies. Methods such as RF shimming and transmit SENSE, which require transceive volume-arrays had been proposed to circumvent the high-field inhomogeneity problem [2]. Currently, the trend in designing transceive volume arrays is to fit the highest feasible number of coil-elements within a given geometry. Consequently, the aperture of each coil element will be small and RF field penetration depth is sacrificed. In addition, with increased number of coil elements, mutual decoupling is harder to control and good channel isolation is difficult to achieve. Therefore, it is very important to consider these two issues when designing a transceive volume-array system. In this work, the development of an optimized, shielded 8-element transceive volume-array for small animal MRI applications at 9.4T is discussed. To take into consideration the mentioned designing issues, a novel radiating structure for the coil element has been proposed. A prototype was constructed and tested in a Bruker 9.4T Biospec MRI system. Simulated and experimental results presented herein demonstrate the potential of the design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Actively Detunable 8-channel Small Animal Transceive Volume Array for 9.4T MRI systems

Introduction Ultra-high field MRI systems for small animals have seen a rapid development over recent years in a continuous effort to enhance SNR and spectral resolution of MRI images. To circumvent the associated high-field B1 inhomogeneity problem, methods such as RF shimming and Transmit SENSE have been proposed [1-2]. To benefit from the advantages of these techniques, dedicated phased-arra...

متن کامل

A Novel 8-Channel Transceive Volume-Array for a 9.4T Animal Scanner

Introduction This work focuses on the design of a novel 8-element TX/RX volume-array for high field animal MRI. The magnetic field strength of current small animal MRI systems is increasing in search of higher SNR and spectral resolution [1]. Along with the move to higher field strengths, RF coil design for small-animal MRI is advancing concurrently [2]. At ultra high field strengths, however, ...

متن کامل

Geometrically Decoupled Phased Array Coils for Mouse Imaging

Introduction: Roemer et al [1] introduced phased array surface coils which offer high SNR over a large field of view. Phased array volume coils, introduced by Hayes et al [2] have high SNR at the surface and centre of the volume. Most array coil designs typically employ a combination of geometrical and additional techniques, such as isolating preamplifiers, for element-to-element decoupling. Th...

متن کامل

Transceive Stripline Arrays for Ultra High Field Parallel Imaging Applications

G. Adriany, P. Van de Moortele, F. Wiesinger, P. Andersen, J. Strupp, X. Zhang, C. J. Snyder, W. Chen, K. P. Pruessmann, P. Boesiger, J. T. Vaughan, K. Ugurbil Center for MR Research, University of Minnesota Medical School, Minneapolis, United States, Institute for Biomedical Engineering, University and ETH Zurich, Switzerland We present four and eight channel transceive stripline arrays for ul...

متن کامل

Tunable Geometric Decoupling Mechanisms for Phased Array Coils

Introduction: After their introduction by Roemer et al [1], phased array coils have become standard in clinical MR imaging. The development of array coils for small animal MRI is of increasing interest. Field strengths of 4.7T and higher are especially suited for small animal work because of the high SNR offered at these field strengths. Isolation preamplifiers are expensive and not ubiquitous ...

متن کامل