Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer

نویسندگان

  • Zeynep Altıparmak
  • Ramazan Yağcı
  • Emre Güler
  • Zeynel Arslanyılmaz
  • Metin Canbal
  • İbrahim F. Hepşen
چکیده

OBJECTIVES To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. MATERIALS AND METHODS Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal higher-order wavefront aberrations (6.0 mm pupil), pachymetry at the central, paracentral, and peripheral zones, and anterior chamber depth (ACD). Repeatability was assessed by calculating the within-subject standard deviation, precision, repeatability, and intraclass correlation coefficient (ICC). Bland-Altman analysis was used for assessing reproducibility. RESULTS Thirty eyes of 30 patients were included. The best ICC values were for corneal pachymetry and ACD. For both observers, acceptable ICC was also achieved for the other parameters, the only exceptions being posterior corneal astigmatism and total high order aberration. The 95% LoA (Limits of Agreement) values for all measurements showed small variability between the two examiners. CONCLUSION The Galilei system provided reliable measurements of anterior segment parameters. Therefore, the instrument can be confidently used for routine clinical use and research purposes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Repeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimp g Analyzer

Address for Correspondence: Zeynep Altıparmak MD, Ulucanlar Eye Training and Research Hospital, Ankara, Turkey Tel.: +90 532 307 91 40 E-mail: [email protected] Received: 02.10.2014 Accepted: 15.02.2015 This article is also published in Turkish under doi:10.4274/tjo.16768 pages 2015;45:243-248 Objectives: To assess the repeatability and reproducibility of anterior segment measurements includi...

متن کامل

Repeatability of Ocular Measurements with a Dual-Scheimpflug Analyzer in Healthy Eyes

PURPOSE To assess the repeatability of the Galilei dual Scheimpflug analyzer (GDSA) in anterior segment examination. METHODS Fifty-two eyes from 52 healthy volunteers were prospectively and consecutively recruited. Anatomic, axial, refractive, and instantaneous parameters were measured with GDSA to provide a complete characterization of the anterior segment. Repeatability was assessed calcula...

متن کامل

Single session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug + Placido device

PURPOSE To analyze single session, intrauser reliability of a Scheimpflug device for anterior chamber (AC) and corneal parameters. METHODS In this observational study, 100 normal candidates underwent Scheimpflug analysis with Sirius 3D Rotating Scheimpflug Camera and Topography System (Costruzione Strumenti Oftalmici, Italy). Two scans in dark room conditions were performed by the same experi...

متن کامل

Comparison of Anterior Segment Measurements Obtained by Three Different Devices in Healthy Eyes

PURPOSE To assess the normal values and the repeatability of the Galilei Dual Scheimpflug Analyzer (GDSA), the biometer IOL Master, and the autokerato/refractometer WAM 5500 in anterior segment examinations. METHODS Eighty-eight eyes from 88 healthy volunteers were prospectively and consecutively recruited. The repeatability was assessed, calculating the intraclass correlation coefficient (IC...

متن کامل

Comparison of Anterior Corneal Curvature Measurements Using a Galilei Dual Scheimpflug Analyzer and Topcon Auto Kerato-Refractometer

Purpose. To compare anterior corneal keratometry (K) measurements taken by a dual Scheimpflug analyzer and an auto kerato-refractometer. Methods. Sixty-four normal eyes underwent keratometric measurements with both devices. The repeatability of the auto kerato-refractometer measurements was assessed by calculating the coefficient of variation (COV). The interdevice agreement was evaluated using...

متن کامل