The biomechanical analysis of three plating fixation systems for periprosthetic femoral fracture near the tip of a total hip arthroplasty
نویسندگان
چکیده
BACKGROUND A variety of techniques are available for fixation of femoral shaft fractures following total hip arthroplasty. The optimal surgical repair method still remains a point of controversy in the literature. However, few studies have quantified the performance of such repair constructs. This study biomechanically examined 3 different screw-plate and cable-plate systems for fixation of periprosthetic femoral fractures near the tip of a total hip arthroplasty. METHODS Twelve pairs of human cadaveric femurs were utilized. Each left femur was prepared for the cemented insertion of the femoral component of a total hip implant. Femoral fractures were created in the femurs and subsequently repaired with Construct A (Zimmer Cable Ready System), Construct B (AO Cable-Plate System), or Construct C (Dall-Miles Cable Grip System). Right femora served as matched intact controls. Axial, torsional, and four-point bending tests were performed to obtain stiffness values. RESULTS All repair systems showed 3.08 to 5.33 times greater axial stiffness over intact control specimens. Four-point normalized bending (0.69 to 0.85) and normalized torsional (0.55 to 0.69) stiffnesses were lower than intact controls for most comparisons. Screw-plates provided either greater or equal stiffness compared to cable-plates in almost all cases. There were no statistical differences between plating systems A, B, or C when compared to each other (p > 0.05). CONCLUSIONS Screw-plate systems provide more optimal mechanical stability than cable-plate systems for periprosthetic femur fractures near the tip of a total hip arthroplasty.
منابع مشابه
Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem
The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...
متن کاملThe use of an interference fit retrograde nail as an adjunct to plate fixation of a complex Vancouver B1 periprosthetic femoral fracture.
As the number of hip arthroplasties performed continues to grow, increasingly complex periprosthetic fractures are encountered. In particular, fractures occurring near the tip of a well-fixed stem, classified as Vancouver B1, have been associated with high rates of failure. Numerous treatment strategies have been recommended including traditional plating, locked plating, cortical allografts as ...
متن کاملAntibiotic-impregnated Cement Plate for the Treatment of Infected Periprosthetic Femoral Fracture after Cementless Total Hip Arthroplasty - A Case Report -
Copyright c 2012 by Korean Hip Society 245 Periprosthetic femoral fracture is a problematic complication of total hip arthroplasty (THA). Although treatment protocols for periprosthetic femoral fracture have been reported, treatment protocols for periprosthetic fracture with accompanying infection have rarely been published. When these two complications occur together, it becomes more difficult...
متن کاملCementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملPrinciples of treatment for periprosthetic femoral shaft fractures around well-fixed total hip arthroplasty.
Postoperative periprosthetic femoral fractures around the stem of a total hip arthroplasty are increasing in frequency. To obtain optimal results, full appreciation of the clinical evaluation, classification, and modern management principles and techniques is required. Although periprosthetic femoral fracture associated with a loose stem requires complex revision arthroplasty, fractures associa...
متن کامل