Effect of room temperature on tests for diagnosing vibration-induced white finger: finger rewarming times and finger systolic blood pressures

نویسندگان

  • Ying Ye
  • Michael J. Griffin
چکیده

PURPOSE This study investigates the effects of room temperature on two standard tests used to assist the diagnosis of vibration-induced white finger (VWF): finger rewarming times and finger systolic blood pressures. METHODS Twelve healthy males and twelve healthy females participated in four sessions to obtain either finger skin temperatures (FSTs) during cooling and rewarming of the hand or finger systolic blood pressures (FSBPs) after local cooling of the fingers to 15 and 10 °C. The measures were obtained with the room temperature at either 20 or 28 °C. RESULTS There were lower baseline finger skin temperatures, longer finger rewarming times, and lower finger systolic blood pressures with the room temperature at 20 than 28 °C. However, percentage reductions in FSBP at 15 and 10 °C relative to 30 °C (i.e. %FSBP) did not differ between the two room temperatures. Females had lower baseline FSTs, longer rewarming times, and lower FSBPs than males, but %FSBPs were similar in males and females. CONCLUSIONS Finger rewarming times after cold provocation are heavily influenced by room temperature and gender. For evaluating peripheral circulatory function using finger rewarming times, the room temperature must be strictly controlled, and a different diagnostic criterion is required for females. The calculation of percentage changes in finger systolic blood pressure at 15 and 10 °C relative to 30 °C reduces effects of both room temperature and gender, and the test may be used in conditions where the ±1 °C tolerance on room temperature required by the current standard cannot be achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of two alternative standardised tests for the vascular component of the hand–arm vibration syndrome (HAVS)

BACKGROUND Vibration-induced white finger (VWF) is the vascular component of the hand-arm vibration syndrome (HAVS). Two tests have been standardised so as to assist the diagnosis of VWF: the measurement of finger rewarming times and the measurement of finger systolic blood pressures (FSBPs). OBJECTIVES This study investigates whether the two tests distinguish between fingers with and without...

متن کامل

Effects of room temperature, seasonal condition and food intake on finger skin temperature during cold exposure test for diagnosing hand-arm vibration syndrome.

For diagnosing the hand-arm vibration syndrome, peripheral circulation and sensory tests immersing one hand in cold water at 10 degrees C for 10 min have been performed widely in Japan. The authors investigated the effects of room temperature, seasonal condition and food intake on the test results, especially finger skin temperature. Six healthy males were examined repeatedly under six differen...

متن کامل

Raynaud's phenomenon in workers exposed to vibration.

Both the finger systolic blood pressure (FSP) and the rewarming test of finger skin are measures of circulation in the finger; the first reflects the vasoconstriction phase and the second the vasodilatation phase. The combinations of the specificity and the sensitivity of these methods were evaluated by a receiver operating characteristic curve (ROC). The material included 37 vibration-induced ...

متن کامل

Assessment of vibration induced white finger: reliability and validity of two tests.

The reliability and validity of two tests (cold water and reactive hyperaemia) designed to confirm a patient's history of vibration induced white finger were studied. The cold water test is a measure of digital rewarming after hand immersion in cold water. Reactive hyperaemia consists of measuring digital rewarming after cold water immersion plus temporary ischaemia imposed on the hand. For ten...

متن کامل

The diagnostic value of finger systolic blood pressure and cold-provocation testing for the vascular component of hand-arm vibration syndrome in health surveillance.

BACKGROUND Hand-arm vibration syndrome (HAVS) is a complex condition with vascular, sensorineural and musculoskeletal components. A number of quantitative tests have been used for assisting in the diagnosis of HAVS and grading disease severity. AIMS To investigate and compare the diagnostic value of finger systolic blood pressure (FSBP) and rewarming of finger skin temperature (FST) following...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 90  شماره 

صفحات  -

تاریخ انتشار 2017