A novel reflex cough testing device
نویسندگان
چکیده
BACKGROUND The reflex cough test is useful for detecting silent aspiration, a risk factor for aspiration pneumonia. However, assessing the risk of aspiration pneumonia requires measuring not only the cough reflex but also cough strength. Currently, no reflex cough testing device is available that can directly measure reflex cough strength. We therefore developed a new testing device that can easily and simultaneously measure cough strength and the time until the cough reflex, and verified whether screening with this new instrument is feasible for evaluating the risk of aspiration pneumonia. METHODS This device consists of a special pipe with a double lumen, a nebulizer, and an electronic spirometer. We used a solution of prescription-grade L-tartaric acid to initiate the cough reflex. The solution was inhaled through a mouthpiece as a microaerosol produced by an ultrasonic nebulizer. The peak cough flow (PCF) of the induced cough was measured with the spirometer. The 70 patients who participated in this study comprised 49 patients without a history of pneumonia (group A), 21 patients with a history of pneumonia (group B), and 10 healthy volunteers (control group). RESULTS With the novel device, PCF and time until cough reflex could be measured without adverse effects. The PCF values were 118.3 ± 64.0 L/min, 47.7 ± 38.5 L/min, and 254.9 ± 83.8 L/min in group A, group B, and the control group, respectively. The PCF of group B was significantly lower than that of group A and the control group (p < 0.0001), while that of group B was significantly lower than that of the control group (p < 0.0001). The time until the cough reflex was 4.2 ± 5.9 s, 7.0 ± 7.0 s, and 1 s in group A, group B, and the control group, respectively. This duration was significantly longer for groups A and B than for the control group (A: p < 0.001, B: p < 0.001), but there was no significant difference between groups A and B (p = 0.0907). CONCLUSION Our newly developed device can easily and simultaneously measure the time until the cough reflex and the strength of involuntary coughs for assessment of patients at risk of aspiration pneumonia.
منابع مشابه
Inhibitory control of the cough reflex by galanin receptors in the caudal nucleus tractus solitarii of the rabbit.
The caudal nucleus tractus solitarii (NTS) is the main central station of cough-related afferents and a strategic site for the modulation of the cough reflex. The similarities between the characteristics of central processing of nociceptive and cough-related inputs led us to hypothesize that galanin, a neuropeptide implicated in the control of pain, could also be involved in the regulation of t...
متن کاملInhibitory control of the cough reflex by galanin receptors in the caudal
26 The caudal nucleus tractus solitarii (NTS) is the main central station of cough-related 27 afferents and a strategic site for the modulation of the cough reflex. The similarities 28 between the characteristics of central processing of nociceptive and cough-related inputs 29 led us to hypothesize that galanin, a neuropeptide implicated in the control of pain, 30 could also be involved in the ...
متن کاملAssessing the laryngeal cough reflex and the risk of developing pneumonia after stroke.
OBJECTIVE To determine the effectiveness of a new reflex cough test, using nebulized tartaric acid, in the evaluation of the laryngeal cough reflex and the development of aspiration pneumonia. STUDY DESIGN In this two-phase study, the cough test assessed the cough reflex in 161 stroke subjects. Phase 1 was a double-blinded prospective study of 40 subjects scheduled to have both modified bariu...
متن کاملSex differences and predictors of objective cough frequency in chronic cough.
BACKGROUND Women are consistently over-represented in specialist cough clinics and known to have a more sensitive cough reflex than men. Whether female sex and other patient characteristics are associated with higher cough rates is not known. A study was conducted to determine the predictors of objective cough frequency in patients presenting to a tertiary referral clinic with chronic cough. ...
متن کاملReview: Effect of drugs on human cough reflex sensitivity to inhaled capsaicin
Capsaicin, the pungent extract of red peppers, has been used in clinical research for almost three decades. Capsaicin has gained favor as the provocative agent of choice to measure cough reflex sensitivity, as it induces cough in a safe, reproducible, and dose-dependent manner. One of the major uses of capsaicin cough challenge testing has been to evaluate the effect of a pharmacological interv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2017