Simulation and Analytical Investigation of Different Combination of Single Phase Power Transformers

ثبت نشده
چکیده

Abstract—In this paper, the equivalent circuit of the ideal singlephase power transformer with its appropriate voltage current measurement was presented. The calculated values of the voltages and currents of the different connections single phase normal transformer and the results of the simulation process are compared. As it can be seen, the calculated results are the same as the simulated results. This paper includes eight possible different transformer connections. Depending on the desired voltage level, step-down and step-up application transformer is considered. Modelling and analysis of a system consisting of an equivalent source, transformer (primary and secondary), and loads are performed to investigate the combinations. The obtained values are simulated in PSpice environment and then how the currents, voltages and phase angle are distributed between them is explained based on calculation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Harmonic Modeling of Inrush Current in Core Type Power Transformers Using Hartley Transform

This paper presents a new method for evaluation and simulation of inrush current in various transformers using operational matrices and Hartley transform. Unlike most of the previous works, time and frequency domain calculations are conducted simultaneously. Mathematical equations are first represented to compute the inrush current based on reiteration and then Hartley transform is used to stud...

متن کامل

Impacts of New Suggested Ferroresonance Limiter on the Stability Domain of Ferroresonance Modes in Power Transformers Considering Metal Oxide Surge Arrester Effect

this work studies the effect of neutral earth resistance on the controlling ferroresonance oscillation in the power transformer including MOV surge arrester. A simple case of ferroresonance circuit in a three phase transformer is used to show this phenomenon and the three-phase transformer core structures including nonlinear core losses are discussed. The effect of MOV surge arrester and neutra...

متن کامل

Power Quality Improvement in Traction Power Supply Networks

AC railway traction loads are usually huge single phase loads. As a result, a significant amount of Negative Sequence Current (NSC) is injected into utility grid. Moreover, harmonics and consumption ofreactive power are further power quality problems that the supply network is encountering. In this paper, acompensation strategy with the aid of Railway Power Conditioner (RPC) is proposed to over...

متن کامل

Transformer-based Single-source Multilevel Inverter with Reduction in Number of Transformers

Single-source binary hybrid multilevel inverters with cascaded transformers have a bulky transformer connected to their main H-bridge cells in each phase. This bulky transformer has been eliminated in this work without any effect on operation and modulation strategies. The proposed topology has significant advantages from view point of dimensions and number of transformers, design of transforme...

متن کامل

A Direct Power Feeding System for AC Railway Networks Using Modular Multilevel Converter

Abstract Traditional railway power supply systems impose substantial power quality problems (PQ) on the utility network, such as unbalance, harmonics and a large amount of reactive power. This paper proposes a topology based on three-phase to single-phase modular multilevel converters (MMC) to obviate these problems. The MMC based traction substations (TSS) are connected directly to the utili...