Nano rough micron patterned titanium for directing osteoblast morphology and adhesion
نویسندگان
چکیده
Previous studies have demonstrated greater functions ofosteoblasts (bone-forming cells) on nanophase compared with conventional metals. Nanophase metals possess a biologically inspired nanostructured surface that mimics the dimensions of constituent components in bone, including collagen and hydroxyapatite. Not only do these components possess dimensions on the nanoscale, they are aligned in a parallel manner creating a defined orientation in bone. To date, research has yet to evaluate the effect that organized nanosurface features can have on the interaction of osteoblasts with material surfaces. Therefore, to determine if surface orientation of features can mediate osteoblast adhesion and morphology, this study investigated osteoblast function on patterned titanium substrates containing alternating regions of micron rough and nano rough surfaces prepared by novel electron beam evaporation techniques. This study was also interested in determining whether or not the size of the patterned regions had an effect on osteoblast behavior and alignment. Results indicated early controlled osteoblast alignment on these patterned materials as well as greater osteoblast adhesion on the nano rough regions of these patterned substrates. Interestingly, decreasing the width of the nano rough regions (from 80 microm to 22 microm) on these patterned substrates resulted in a decreased number of osteoblasts adhering to these areas. Changes in the width of the nano rough regions also resulted in changes in osteoblast morphology, thus, suggesting there is an optimal pattern dimension that osteoblasts prefer. In summary, results of this study provided evidence that aligned nanophase metal features on the surface of titanium improved early osteoblast functions (morphology and adhesion) promising for their long term functions, criteria necessary to improve orthopedic implant efficacy.
منابع مشابه
Increased Osteoblast Adhesion on Nano-rough Anodized Titanium and CoCrMo
One approach to improve biological properties of current titanium and CoCrMo implant is to mimic the nanostructures of bone. Surface modification via anodization is popular to create such nanometer surface features on these metallic implants. The objective of the present study was to anodize titanium and CoCrMo and then determine osteoblast adhesion on such materials. Hydrofluoric acid was used...
متن کاملEnhanced osteoblast adhesion on nanostructured selenium compacts for anti-cancer orthopedic applications
Metallic bone implants possess numerous problems limiting their long-term efficacy, such as poor prolonged osseointegration, stress shielding, and corrosion under in vivo environments. Such problems are compounded for bone cancer patients since numerous patients receive orthopedic implants after cancerous bone resection. Unfortunately, current orthopedic materials were not originally developed ...
متن کاملIn vitro preliminary study of osteoblast response to surface roughness of titanium discs and topical application of melatonin
OBJECTIVES To observe human osteoblast behavior cultured in vitro on titanium discs (Ti) in relation to surface roughness and melatonin application. STUDY DESIGN Human osteoblasts (MG-63) were cultured on 60 Ti6Al4V discs divided into three groups: Group I: discs treated with dual acid etching; Group II dual acid etching and blasting with calcium phosphate particles; Group III (control) machi...
متن کاملComparative Endothelial Cell Response on Topographically Patterned Titanium and Silicon Substrates with Micrometer to Sub-Micrometer Feature Sizes
In this work, we evaluate the in vitro response of endothelial cells (EC) to variation in precisely-defined, micrometer to sub-micrometer scale topography on two different substrate materials, titanium (Ti) and silicon (Si). Both substrates possess identically-patterned surfaces composed of microfabricated, groove-based gratings with groove widths ranging from 0.5 to 50 µm, grating pitch twice ...
متن کاملPeen treatment on a titanium implant: effect of roughness, osteoblast cell functions, and bonding with bone cement
Implant failure due to poor integration of the implant with the surrounding biomaterial is a common problem in various orthopedic and orthodontic surgeries. Implant fixation mostly depends upon the implant surface topography. Micron to nanosize circular-shaped groove architecture with adequate surface roughness can enhance the mechanical interlock and osseointegration of an implant with the hos...
متن کامل