Assessment of craniospinal arteriovenous malformations at 3T with highly temporally and highly spatially resolved contrast-enhanced MR angiography.

نویسندگان

  • R S Saleh
  • D G Lohan
  • J P Villablanca
  • G Duckwiler
  • S T Kee
  • J P Finn
چکیده

BACKGROUND AND PURPOSE Patients with arteriovenous malformation (AVM) are known to have an elevated risk of complications with conventional catheter angiography (CCA) but nonetheless require monitoring of hemodynamics. Thus, we aimed to evaluate both anatomy and hemodynamics in patients with AVM noninvasively by using contrast-enhanced MR angiography (CE-MRA) at 3T and to compare the results with CCA. MATERIALS AND METHODS Institutional review board approval and informed consent were obtained for this Health Insurance Portability and Accountability Act-compliant study. Twenty control subjects without vascular malformation (6 men, 18-70 years of age) and 10 patients with AVMs (6 men, 20-74 years of age) underwent supra-aortic time-resolved and high-spatial-resolution CE-MRA at 3T. Large-field-of-view coronal acquisitions extending from the root of the aorta to the cranial vertex were obtained for both MRA techniques. Image quality was assessed by 2 specialized radiologists by using a 4-point scale. AVM characteristics and nidus size were evaluated by using both CE-MRA and CCA in all patients. RESULTS In patients, 96.6% (319/330) of arterial segments on high-spatial-resolution MRA and 87.7% (272/310) of arterial segments on time-resolved MRA were graded excellent/good. MRA showed 100% specificity for detecting feeding arteries and venous drainage (n = 8) and complete obliteration of the AVM in 2 cases (concordance with CCA). Nidus diameters measured by both MRA and CCA resulted in a very strong correlation (r = 0.99) with a mild overestimation by MRA (0.10 cm by using the Bland-Altman plot). CONCLUSION By combining highly temporally resolved and highly spatially resolved MRA at 3T as complementary studies, one can assess vascular anatomy and hemodynamics noninvasively in patients with AVM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic 3D MR angiography of intra- and extracranial vascular malformations at 3T: a technical note.

Time-resolved, contrast-enhanced 3D MR angiography combined with parallel imaging at 3T was applied to an intracranial arteriovenous malformation, a dural arteriovenous fistula, and an extracranial facial arteriovenous malformation. The temporal resolution was one image every 1.5 seconds. Arterial feeders were depicted in all three cases. Early venous drainage was observed in the intracerebral ...

متن کامل

Intracranial time-resolved contrast-enhanced MR angiography at 3T.

BACKGROUND AND PURPOSE A method is presented for high-temporal-resolution MR angiography (MRA) using a combination of undersampling strategies and a high-field (3T) scanner. Currently, the evaluation of cerebrovascular disorders involving arteriovenous shunting or retrograde flow is accomplished with conventional radiographic digital subtraction angiography, because of its high spatial and temp...

متن کامل

Comprehensive Magnetic Resonance evaluation of vascular malformations at 3T: comparison of Time-resolved Angiography With Interleaved Stochastic Trajectories (TWIST) with standard 3D contrast enhanced MR Angiography (ceMRA)

(A) TWIST image in early arterial phase showing capillary lakes (arrow head). (B) TWIST image 2.2 sec after (A) showing development of tiny early draining veins (arrow). (C) Standard 3d ceMRA in the arterial phase demonstrating significant venous contamination without evidence of capillary shunting. Comprehensive Magnetic Resonance evaluation of vascular malformations at 3T: comparison of Time-...

متن کامل

Three-dimensional contrast-enhanced MR angiography of the extracranial carotid arteries: two techniques.

Two methods of contrast-enhanced dynamic 3-D MR angiography of the head and neck are demonstrated. In the first, arterial and arteriovenous phases are temporally resolved by timing contrast injection such that maximum arteriovenous signal intensity difference is matched to acquisition of central k-space. A second, faster sequence allows for temporal resolution of arterial, early arteriovenous, ...

متن کامل

Time-resolved contrast-enhanced MR angiography of spinal vascular malformations.

BACKGROUND AND PURPOSE The diagnosis of spinal vascular malformations may be challenging on conventional MR imaging because neither the location of the signal abnormality in the spinal cord nor the level of the abnormal flow voids correlates with the level of the fistula. We conducted a retrospective evaluation of the utility of using a time-resolved imaging of contrast kinetics sequence in the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 2008