An analytical energy-loss line shape for high depth resolution in ion-beam analysis
نویسندگان
چکیده
The knowledge of the energy-loss distribution in a single ion-atom collision is a prerequisite for subnanometric resolution in depth-profiling techniques such as Nuclear Reaction Analysis (NRA) and Medium Energy Ion-Scattering (MEIS). The usual Gaussian approximation specified by the stopping power and energy straggling is not valid for near surface regions of solids, where subnanometric or monolayer resolution can be achieved. In this work we propose an analytical formula for the line shape to replace the usual Gaussian distribution widely used in low-resolution ion-beam analysis. Furthermore, we provide a simple physical method to derive the corresponding shape parameters. We also present a comparison with full coupled-channel calculations as well as with experimental data at nearly single collision conditions. PACS numbers: 34.50.Bw , 61.85.+p, 34.50. Fa, 79.20.Rf.
منابع مشابه
Depth profiles and resolution limits in accelerator-based solid state analysis.
A ubiquitous problem in solid state analysis is the determination of the elemental composition of a sample as a function of the depth. The determination of the depth profiles from ion-beam experiments is an ill-posed inversion problem due to ion-beam and detector-induced energy spreads as well as energy-loss straggling and small-angle scattering effects. The inversion problem is solved in the f...
متن کاملImpact of Various Beam Parameters on Lateral Scattering in Proton and Carbon-ion Therapy
Background: In radiation therapy with ion beams, lateral distributions of absorbed dose in the tissue are important. Heavy ion therapy, such as carbon-ion therapy, is a novel technique of high-precision external radiotherapy which has advantages over proton therapy in terms of dose locality and biological effectiveness.Methods: In this study, we used Monte Carlo method-based Geant4 toolkit to s...
متن کاملEvaluation of variable relative biological effectiveness and the creation of homogenous biological dose in the tumor region in helium ion radiation to the V79 cell line
In radiation therapy, ions heavier than proton have more biological advantages than a proton beam. Recently, ion helium has been considered due to high linear energy transfer (LET) to the medium and a higher relative biological effect (RBE). To design the spread-out Bragg peak (SOBP) of biological dose for radiation with any type of ion, we need exact values of RBE, which is dependent to dose, ...
متن کاملUltra-Sharpening of Diamond Stylus by 500 eV O+/O2 + Ion Beam Machining without Facet and Ripple Formation
The price of single point diamond tools with a sharp tip is very high due to complex machining process and highly expensive machining equipments. Yet, the performance is not quite satisfactory. In this paper, we have presented a very simple and cost effective machining process for the sharpening and polishing of diamond stylus using low energy reactive ion beam machining (RIBM). In our method, ...
متن کاملAnalytical Electron Microscopy — Study of All Solid-State Batteries
This chapter focuses on the recent development and optimization of analytical electron microscopy to understand the dynamic changes in the bulk and interfaces of electrodes and electrolytes within all solidstate batteries. Three major aspects are covered: (1) design and fabrication of all solid-state batteries that remain functional after careful focused ion beam (FIB) processing; (2) enablemen...
متن کامل