Safety of heparin-coated circuits in primates during deep hypothermic cardiopulmonary bypass.
نویسندگان
چکیده
The purpose of this study is to evaluate the biologic impact of heparin-coated circuits without systemic heparinization during deep hypothermia. Baboons (n=6) were placed on a heparin-coated pediatric closed-circuit cardiopulmonary bypass (CPB) system and cooled to 18 degrees C. A control group (n=7) underwent similar protocol with a non heparin-coated circuit and received systemic heparin. Either low flow at 0.5 L/min/m 2 (n=8; 4 in each group) or circulatory arrest (n=5; 2 in experimental group and 3 in control group) was used during deep hypothermia. Samples for complete blood count (CBC), hepatic and renal function tests, activated clotting time (ACT) and thrombelastogram (TEG) were obtained before, during, and after bypass. Cerebral blood flow was measured using Xenon-133 and autopsies were performed to assess end-organ damage. The ACT returned to baseline in both groups, and renal and hepatic function were within normal limits. There was no significant difference between the TEG values between the groups post bypass. Fibrin split products were absent and fibrinogen levels were normal in both groups following bypass. Cerebral blood flows were equivalent in both groups before and after bypass, although in the heparin-coated group cerebral blood flows were significantly higher during CPB. There were no brain histologic changes in the heparin-coated group and one focal cortical infarct in the control group. This study suggests that hypothermia induced a state of anticoagulation that did not result in thrombus formation or end organ dysfunction during CPB with a heparin-coated circuit.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Heparin Coated Cardiopulmonary Bypass Circuits in Coronary Artery Surgery- A Clinical Study
Abstract------------------Cardiopulmonary bypass with systemic heparinization causes trauma to blood cells and coagulation defects. Artificial surfaces could be coated by end-linkage binding of heparin (Carmeda Bioactive Surface CBASTM). The use of such surfaces during cardiopulmonary bypass in animals resulted in less postoperative blood loss and better preservation of blood cells. Heparin-coa...
متن کاملCoronary artery bypass surgery with heparin-coated perfusion circuits and low-dose heparinization.
OBJECTIVE To evaluate the safety and efficacy of heparin-coated perfusion circuits with low-dose heparinization and centrifugal pumping compared with the standard method during coronary artery bypass grafting. DESIGN Prospective, randomized, single-blind clinical trial. SETTING A primary care institution. PATIENTS Ninety patients who underwent first-time elective coronary artery bypass gr...
متن کاملImproving cardiopulmonary bypass: heparin-coated circuits.
Heparin-coated circuits have been repeatedly proven to reduce the inflammatory response and foreign surface activation triggered upon initiation of cardiopulmonary bypass (CPB). In recent years, increasing numbers of studies are proving significant reductions in postoperative blood loss and transfusion requirements and improvements in clinical outcomes as a result of heparin-coated circuits. Th...
متن کاملRetrospective analysis of outcome data with regards to the use of Phisio®-, Bioline®- or Softline®-coated cardiopulmonary bypass circuits in cardiac surgery.
BACKGROUND Numerous cardiopulmonary bypass circuits with various coatings designed to reduce the inflammatory response and to provide better hemocompatibility are available. The aim of this study was to compare the effect of phosphorylcholine-coated, albumin-heparin-coated and synthetic polymer-coated perfusion tubing systems on patient outcome. METHODS We performed a retrospective database r...
متن کاملInflammatory response after coronary revascularization: off-pump versus on-pump (heparin-coated circuits and poly2methoxyethylacrylate-coated circuits).
OBJECTIVE Off-pump coronary artery bypass grafting (OPCAB) may reduce the inflammatory response associated with cardiopulmonary bypass (CPB) and contribute to minimizing postoperative complications. Heparin-coated circuits and poly2methoxyethylacrylate (PMEA)-coated circuits were developed to reduce such complications. We compared the postoperative inflammatory response with or without CPB. M...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 25 1 شماره
صفحات -
تاریخ انتشار 1993