Experimental Estimate of Helical Inducer Blade Force
نویسندگان
چکیده
An attachment of inducer is a powerful method to improve the cavitation performance of a turbo-pump. Cavitation surge phenomena, occurring under the severe suction pressure at a partial flow rate, is focused in the present paper. Flow measurements were carried out at the inlet and outlet sections of a flat-plate helical inducer with the solidity of 2.0 and tip blade angle of 11o by using a total-head yaw-meter with a phase locked sampling method in one period of the shaft rotation or the cavitation oscillation. Time variation of the flow distributions during the oscillation is clarified with observed cavitation behaviors. After these results are compared with those in conditions just before and after the oscillations, the fluctuating blade forces are estimated from the blade to blade distributions of casing wall pressures measured in these conditions.
منابع مشابه
The Analytic Technique and Experimental Research Methods of Post-buckling about Slender Rod Strings in Wellbore
The buckling behavior of rod strings in wellbore is one of the key issues in petroleum engineering. The slender rod strings in vertical wellbore were selected as research objects. Based on the energy method, the critical load formulas of sinusoidal and helical buckling were derived for the string with the bottom of the wellbore pressure. According to the sinusoidal and helical buckling’s geomet...
متن کاملExperimental Study on Flow Characteristics Around Twin Wind Blades (RESEARCH NOTE)
In the current study, twin wind blades are designed, fabricated and the effect of various gap ratio (g*) at various angle of attacks (α) on a next to each other twin wind blades are examined in an open-channel wind tunnel. Aerodynamic forces and moments are determined by using three-constraint force balancer. For gap ratio of zero, the aerodynamic attributes are like those of a solitary wind bl...
متن کاملLife Estimate of a Compressor Blade through Fractography
Failure analysis of fractured components provides some information about the causes and conditions of fracture. Fractography is an indispensable part of the failure analysis as it is usually the only means by which the failure mechanism can be established. By using fractography, some information such as component’s life, values of the stress intensity factor and the applied stress can be calcul...
متن کاملBackout of the helical blade of proximal femoral nail antirotation and accompanying fracture nonunion.
This article describes a case of backout of the helical blade, a rare complication of proximal femoral nail antirotation. A 31-year-old man had sustained a trochanteric fracture of his right femur. Fracture fixation using proximal femoral nail antirotation and autologous bone grafting 7 months later were performed at another hospital. However, bony union was not obtained, and the patient's pain...
متن کاملPelvic migration of the helical blade after treatment of transtrochanteric fracture using a proximal femoral nail☆
Proximal femoral nails with a helical blade are a new generation of implants used for treating transtrochanteric fractures. The blade design provides rotational and angular stability for the fracture. Despite greater biomechanical resistance, they sometimes present complications. In the literature, there are some reports of cases of perforation of the femoral head caused by helical blades. Here...
متن کامل