Measurements of hydrogen sulfide (H2S) using PTR-MS: calibration, humidity dependence, inter-comparison and results from field studies in an oil and gas production region

نویسندگان

  • R. Li
  • C. Warneke
  • M. Graus
  • R. Field
  • F. Geiger
  • P. R. Veres
  • J. Soltis
  • S.-M. Li
  • S. M. Murphy
  • C. Sweeney
  • G. Pétron
  • J. M. Roberts
  • J. de Gouw
چکیده

Natural gas production is associated with emissions of several trace gases, some of them classified as air toxics. While volatile organic compounds (VOCs) have received much attention, hydrogen sulfide (H2S) can also be of concern due to the known health impacts of exposure to this hazardous air pollutant. Here, we present quantitative, fast time-response measurements of H2S using protontransfer-reaction mass-spectrometry (PTR-MS) instruments. An ultra-light-weight PTR-MS (ULW-PTR-MS) in a mobile laboratory was operated for measurements of VOCs and H2S in a gas and oil field during the Uintah Basin Winter Ozone Study (UBWOS) 2012 campaign. Measurements of VOCs and H2S by a PTR-MS were also made at the Horse Pool ground site in the Uintah Basin during UBWOS 2013. The H2S measurement by PTR-MS is strongly humidity dependent because the proton affinity of H2S is only slightly higher than that of water. The H2S sensitivity of PTR-MS ranged between 0.6–1.4 ncps ppbv−1 during UBWOS 2013. We compare the humidity dependence determined in the laboratory with in-field calibrations and determine the H2S mixing ratios for the mobile and ground measurements. The PTR-MS measurements at Horse Pool are evaluated by comparison with simultaneous H2S measurements using a PTR time-offlight MS (PTR-ToF-MS) and a Picarro cavity ring down spectroscopy (CRDS) instrument for H2S / CH4. On average 0.6± 0.3 ppbv H2S was present at Horse Pool during UBWOS 2013. The correlation between H2S and methane enhancements suggests that the source of H2S is associated with oil and gas extraction in the basin. Significant H2S mixing ratios of up to 9 ppmv downwind of storage tanks were observed during the mobile measurements. This study suggests that H2S emissions associated with oil and gas production can lead to short-term high levels close to point sources, and elevated background levels away from those sources. In addition, our work has demonstrated that PTR-MS can make reliable measurements of H2S at levels below 1 ppbv. Published by Copernicus Publications on behalf of the European Geosciences Union. 3598 R. Li et al.: Measurements of hydrogen sulfide (H2S) using PTR-MS

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation of Graphene-amine Nanofluid for Absorption of Carbon Dioxide (CO2) and Hydrogen Sulfide (H2S) from a Natural Gas Stream in a Wetted Wall Column

    In this study, it was shown that how CO2 and H2S were removed from a natural gas stream, using a nanofluid containing nanoporous graphene in Diehanolamine (DEA). Before running the experiments, the appropriate values were chosen for the nanosheet dosage and the liquid and gas flow rates in the absorption experiments, which were performed in a laboratory scale wetted wall column. In the expe...

متن کامل

Technical Note: Determination of formaldehyde mixing ratios in air with PTR-MS: laboratory experiments and field measurements

Formaldehyde (HCHO), the most abundant carbonyl compound in the atmosphere, is generated as an intermediate product in the oxidation of nonmethane hydrocarbons. Proton transfer reaction mass spectrometry (PTR-MS) has the capability to detect HCHO from ion signals at m/z 31 with high time-resolution. However, the detection sensitivity is low compared to other detectable species, and is considera...

متن کامل

Removal of Hydrogen Sulfide from Septic Tank by Vermicomposting Bio Filter

Background & Aims of the Study: Hydrogen sulfide (H2S) is a colorless and highly toxic, easily dissolved in water, flammable and explosive gas. Hydrogen sulfide gas is the main cause of odor emissions from municipal sewage plants. One method for removal of hydrogen sulfide gas is the use of biological systems, biofilter. The aim of this study was to survey removal hydrogen sulfide provide in se...

متن کامل

Performance of Single Point Monitor in Measuring Ammonia and Hydrogen Sulfide Gases

Performance of Single Point Monitors (SPMs) was evaluated for measuring aerial ammonia (NH3, 0 to 30 ppm) and hydrogen sulfide (H2S, 0 to 90 ppb) under laboratory and field conditions. Calibration gas or NH3/H2S−ladden air at various dew−point temperatures (tdp) were introduced simultaneously to the SPMs under evaluation and a chemiluminescence NH3 analyzer or a pulsed−fluorescence H2S analyzer...

متن کامل

A Theoretical Study of H2S and CO2 Interaction with the Single-Walled Nitrogen Doped Carbon Nanotubes

The physical adsorption of hydrogen sulfide and carbon dioxide gases on the zigzag (5,0) carbon nanotubes doped with nitrogen was investigated through the application of B3LYP/6-31G* at the level of theory on Gaussian 03 software. A variety of stable and high abundance structures of nitrogen doped carbon nanotubes were considered in order to study the interaction between the mentioned gases in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014