Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program.
نویسندگان
چکیده
PURPOSE To assess cancer detection rates, false-positive rates before arbitration, positive predictive values for women recalled after arbitration, and the type of cancers detected with use of digital mammography alone and combined with tomosynthesis in a large prospective screening trial. MATERIALS AND METHODS A prospective, reader- and modality-balanced screening study of participants undergoing combined mammography plus tomosynthesis, the results of which were read independently by four different radiologists, is under way. The study was approved by a regional ethics committee, and all participants provided written informed consent. The authors performed a preplanned interim analysis of results from 12,631 examinations interpreted by using mammography alone and mammography plus tomosynthesis from November 22, 2010, to December 31, 2011. Analyses were based on marginal log-linear models for binary data, accounting for correlated interpretations and adjusting for reader-specific performance levels by using a two-sided significance level of .0294. RESULTS Detection rates, including those for invasive and in situ cancers, were 6.1 per 1000 examinations for mammography alone and 8.0 per 1000 examinations for mammography plus tomosynthesis (27% increase, adjusted for reader; P = .001). False-positive rates before arbitration were 61.1 per 1000 examinations with mammography alone and 53.1 per 1000 examinations with mammography plus tomosynthesis (15% decrease, adjusted for reader; P < .001). After arbitration, positive predictive values for recalled patients with cancers verified later were comparable (29.1% and 28.5%, respectively, with mammography alone and mammography plus tomosynthesis; P = .72). Twenty-five additional invasive cancers were detected with mammography plus tomosynthesis (40% increase, adjusted for reader; P < .001). The mean interpretation time was 45 seconds for mammography alone and 91 seconds for mammography plus tomosynthesis (P < .001). CONCLUSION The use of mammography plus tomosynthesis in a screening environment resulted in a significantly higher cancer detection rate and enabled the detection of more invasive cancers. Clinical trial registration no. NCT01248546.
منابع مشابه
Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU
Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...
متن کاملAddition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations.
PURPOSE To determine the effect of implementing a screening tomosynthesis program on real-world clinical performance by quantifying differences between interpretation times for conventional screening mammography and combined tomosynthesis and mammography for multiple participating radiologists with a wide range of experience in a large academic center. MATERIALS AND METHODS In this HIPAA-comp...
متن کاملA comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis.
AIM To measure the change in diagnostic accuracy of conventional film-screen mammography and full-field digital mammography (FFDM) with the addition of digital breast tomosynthesis (DBT) in women recalled for assessment following routine screening. MATERIALS AND METHODS Ethics approval for the study was granted. Women recalled for assessment following routine screening with screen-film mammog...
متن کاملClinical Performance of Synthesized Two-dimensional Mammography Combined with Tomosynthesis in a Large Screening Population.
Purpose To compare the clinical performance of synthesized two-dimensional (s2D) mammography combined with digital breast tomosynthesis (DBT) with that of full-field digital mammography (FFDM) alone and FFDM combined with DBT in a large community-based screening population by analyzing recall rate, positive predictive value, and cancer detection rate. Materials and Methods This was a retrospect...
متن کاملImplementation of Synthesized Two-dimensional Mammography in a Population-based Digital Breast Tomosynthesis Screening Program.
Purpose To evaluate the early implementation of synthesized two-dimensional (s2D) mammography in a population screened entirely with s2D and digital breast tomosynthesis (DBT) (referred to as s2D/DBT) and compare recall rates and cancer detection rates to historic outcomes of digital mammography combined with DBT (referred to as digital mammography/DBT) screening. Materials and Methods This was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 267 1 شماره
صفحات -
تاریخ انتشار 2013