Voltage Flicker Prediction for Two Simultaneously Operated Ac Arc Furnaces
نویسندگان
چکیده
An EMTP-based arc furnace model was developed for evaluation of flicker concerns associated with supplying a large integrated steel mill as they go from one to two furnace operation and as system changes are implemented that will affect the short circuit capacity at the 230 kV power supply substation. The model includes a dynamic arc representation which is designed to be characteristic of the initial portions of the melt cycle when the arc characteristics are the most variable (worst flicker conditions). The flicker calculations are verified using previous measurements with one furnace operation. Flicker simulations were then performed to evaluate a variety of different possible system strengths with both one and two furnaces in operation. The primary flicker measure used for this study is the unweighted rms value of the fluctuation envelope, expressed as a percentage of the rms line-to-ground voltage magnitude.
منابع مشابه
New Strategy of DC Electrical Arc Furnace Converter for Mitigation of Voltage Fluctuations and Comparative Flicker Voltage in AC and DC Furnaces
A novel method to mitigate voltage flicker problem usually caused by DC Arc Furnaces has been presented in this paper. This method called Direct Current Ripple Re-injection is applied to a multi-step switching reactor in the output of the AC/DC converter to make the output load current as smoother as possible. This method would lessen harmonic effects properly. The proposed approach is simulate...
متن کاملPower Quality and Electrical Arc Furnaces
The chapter covers general issues related to power quality in Electric Arc Furnaces. The use of electric arc furnaces (EAF) for steelmaking has grown dramatically in the last decade. Of the steel made today 36% is produced by the electric arc furnace route and this share will increase to 50 by 2030. The electric arc furnaces are used for melting and refining metals, mainly iron in the steel pro...
متن کاملVoltage Flicker Recognition due to Electric Arc Furnaces via Wavelet Transform Applications
Electric Arc Furnaces (EAFs), widely used for steel production industries, are highly nonlinear time-variant disturbing loads because of the random change of the electric arc length results in arc voltage and furnace/supply current fluctuations. Consequently, Power Quality (PQ) problems such as undesirable variations of reactive power, poor power factor, harmonics, and voltage flickers may appe...
متن کاملA Comparison between SVC and STATCOM in Flicker Mitigation of Electric Arc Furnace using Practical Recorded Data
Electric arc furnace (EAF) is one of the largest loads in electric power systems. It is highly time varying and nonlinear. Its reactive power variations cause voltage fluctuations in nearby system which is known as flicker. On the other hand the nonlinear voltage-current characteristic causes strong voltage and current harmonics in EAF. To this end Flexible AC Transmission Systems (FACTS) techn...
متن کاملHarmonics and Flicker Analysis in Arc Furnace Power Systems
This paper presents guidelines for the accurate evaluation of harmonics and flicker generated by ac electric arc furnaces, and its propagation through transmission and distribution systems. It is presented a typical case where a HV system supplies a high capacity arc furnace. The electrical network is simulated using the ATP version of the EMTP where a non-linear time-varying three-phase arc mo...
متن کامل