Development and evaluation of a novel four-electrode device system for monitoring skin impedance.
نویسندگان
چکیده
Qi, meridians, and acupoints are important issues in Chinese medicine. One of the theories claims that acupuncture points and meridians have unique electrical properties. The associations between acupuncture points or meridians and special electrical properties are still under debate. In the current study, we introduced and explained a device for this kind of research and evaluated the reliability of this device as well as effects of pressure, cleaning the skin by alcohol and exfoliation on electrical skin measurements. Fifteen subjects (10 female, 5 male) were recruited to participate in the study. An impedance meter based on the four-electrode technique was designed and fabricated specifically for this study. The effects of pressure, cleaning of the skin by alcohol, and exfoliation on electrical skin impedance were evaluated separately. The device repeatability was also evaluated 30 times in a 30 minutes period. Scale weight up to 200 grams, cleaning the skin with alcohol, and exfoliation didn't affect the performance of this device. The device performance didn't change significantly during the 30 minutes measurement either. The new system we evaluated can be a reliable tool for researches on electrical skin impedance in acupuncture, as its performance is fairly stable even in the presence of various confounding factors such as various pressures on the probe, cleaning the skin with alcohol and exfoliation.
منابع مشابه
Skin Impedance Measurements for Acupuncture Research: Development of a Continuous Recording System
Skin impedance at acupuncture points (APs) has been used as a diagnostic/therapeutic aid for more than 50 years. Currently, researchers are evaluating the electrophysiologic properties of APs as a possible means of understanding acupuncture's mechanism. To comprehensively assess the diagnostic, therapeutic and mechanistic implications of acupuncture point skin impedance, a device capable of rel...
متن کاملBiomedical Application of a Novel Nanostructured-based Electrochemical Platform for Therapeutic Monitoring of an Antiepileptic Drug; Gabapentin
Herein, gold nanoparticle had been successfully synthesized through a simple, inexpensive and clean electrochemical technique. Gold nanoparticles were directly deposited on the electrode surface using an electrochemical strategy. Then, the electrochemical deposition parameters (such as applied potential and deposition time) were optimized. 1.1 V and 250 s were applied as the optimal electrodepo...
متن کاملEvaluation of the Slope of Amplitude Growth Function Changes of the Electrically Evoked Action Potential in Three Months after Receiving the Device in Children with Cochlear Implant
Objective: In neural response telemetry, intracochlear electrodes stimulate the auditory nerve and record the neural responses. The electrical stimulation is sent to the auditory nerve by an electrode and the resulted response, called electrically evoked compound action potential, is recorded by an adjacent electrode. The most important clinical applications of this test are evaluation and moni...
متن کاملECG Monitoring Garment Using Conductive Carbon Paste for Reduced Motion Artifacts
The heart is a fundamental organ of the human circulatory system and the continuous measurement of electrocardiogram (ECG) signals is of great importance for pre-detection of heart diseases. Dry electrodes that do not require electrolyte gel have been developed for wearable ECG monitoring applications. However, this kind of electrode often introduces motion artifacts because of the high contact...
متن کاملAn Improved Micro-power Pre-amplifier for Dry-electrode ECG Recording
This paper describes the development of a very low-power pre-amplifier intended for use in pasteless-electrode recording of the human electrocardiogram. The expected input signal range is 100μV 10mV from a lead II electrode configuration. The amplifier provides a gain of 42dB in a 3dB bandwidth of 0.05Hz 2kHz with an input impedance of 280MΩ and a CMRR of greater than 80dB. Its gain and phase c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- African journal of traditional, complementary, and alternative medicines : AJTCAM
دوره 9 4 شماره
صفحات -
تاریخ انتشار 2012