Radiological examination of the intrathecal position of microcatheters in continuous spinal anaesthesia.

نویسندگان

  • T Standl
  • H Beck
چکیده

There have been few studies of the intrathecal position of spinal catheters in continuous spinal anaesthesia. This prospective study was designed to examine radiologically the intrathecal position of 28-gauge spinal catheters. We studied the entry into the subarachnoid space and the intrathecal position of 68 spinal catheters. In 50%, the catheters passed in a cranial direction, in 34% the catheters remained at the level of the puncture site and in 16% the catheters were directed caudally. The intrathecal position of the catheters did not depend on the level of the lumbar puncture (P = 0.6246), but was dependent on the position of the patient during insertion of the catheter (P = 0.0093), and on the depth of insertion (P = 0.0099). Our study suggests that patients should be in a sitting position during insertion of a subarachnoid microcatheter and that the depth of insertion should not exceed 4 cm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does speed of intrathecal injection affect the distribution of 0.5% hyperbaric bupivacaine?

We have evaluated the influence of speed of intrathecal injection on lateral distribution of 0.5% hyperbaric bupivacaine. We studied 60 patients undergoing lower limb surgery who were placed in the lateral position with the operative side in the dependent position. After dural puncture (25-gauge Whitacre spinal needle), the needle aperture was turned towards the dependent side and 0.5% hyperbar...

متن کامل

Effect of nimodipine on regression of spinal analgesia.

We have investigated the effect of infusion of nimodipine on the spread of spinal anaesthesia in 50 patients undergoing transurethral procedures. Patients were allocated randomly to receive during operation continuous infusion of nimodipine 10 ml h-1 (group N, n = 25) or normal saline (group C, n = 25) in a double-blind manner. All patients received hyperbaric lidocaine 100 mg (5% in 8% dextros...

متن کامل

مقایسه اثر بوپیواکائین و لیدوکائین اینتراتکال بر میزان بروز افت فشار خون و تهوع واستفراغ در سزارین

        Aim and Background:   Hypotension and nausea are common side effects during spinal anesthesia. This study compared the incidence of hypotension and nausea-vomiting induced by bupivacaine and lidocaine in parturients undergoing caesarean section under spinal anaesthesia. Methods and Materials:   In this...

متن کامل

Effect of the trendelenberg position on spinal anaesthesia with hyperbaric bupivacaine.

In a double-blind study, the effect of the Trendelenberg position was compared with the supine, in 20 patients following intrathecal injection of 3 ml of 0.5% bupivacaine in 8% glucose. All patients had blocks suitable for abdominal surgery. Although the mean spread was greater in those patients titled head-down, this was not statistically significant. The variation of the spread around the mea...

متن کامل

Spinal anaesthesia for caesarean section. The use of 0.5% bupivacaine.

Subarachnoid anaesthesia was induced with 0.5% bupivacaine 2-3.5 ml in 33 women scheduled for elective Caesarean section. Three patients failed to develop adequate analgesia with bupivacaine but were managed satisfactorily with heavy cinchocaine. All the other patients developed adequate analgesia eventually. Since the spread of analgesia was uniquely dependent on posture a new hypothesis is pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 71 6  شماره 

صفحات  -

تاریخ انتشار 1993