Direct fluorescent-antibody method for the diagnosis of Pneumocystis carinii pneumonitis from sputa or tracheal aspirates from humans.

نویسندگان

  • S K Lim
  • W C Eveland
  • R J Porter
چکیده

A direct fluorescent antibody (DFA) method was applied to sputum or tracheal aspirate from 68 patients with clinical or radiological evidence suggesting Pneumocystis carinii pneumonitis, and to 50 control patients. P. carinii was detected by DFA in specimens from 33 of the 69 clinical cases and 3 of the 50 controls. Specimens of lung from 11 of 33 DFA-positive cases were examined histologically, and 9 were positive. Four of 35 DFA-negative cases were examined histologically, and all were negative. Sputa or tracheal aspirates from 6 patients who were positive by both DFA and histological examination were examined also by methenamine silver staining; none could be diagnosed conclusively by this method. The results indicate that the DFA method is a sensitive and dependable procedure for the laboratory diagnosis of P. carinii pneumonitis in man.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid detection of Pneumocystis carinii using a direct fluorescent monoclonal antibody stain.

A collaborative study was undertaken at two institutions to assess the performance of a direct fluorescent-antibody stain for the detection of Pneumocystis carinii in respiratory specimens from patients with known or suspected human immunodeficiency virus type 1 infections. A total of 163 specimens (125 induced sputa, 37 bronchoalveolar lavage fluids, and 1 tracheal aspirate) from 124 patients ...

متن کامل

Diagnosis of Pneumocystis carinii pneumonia from non-invasive sampling of respiratory secretions.

An infant infected with HIV presented with fever, tachypnoea, hypoxia, and radiological evidence of bilateral pneumonitis. Fluorescent antibody technique identified Pneumocystis carinii within 24 hours from secretions obtained by nasopharyngeal aspiration. This rapid, non-invasive method should be the first line investigation of suspected P carinii pneumonia in immunocompromised patients.

متن کامل

Pneumocystis carinii pneumonitis: a serological study.

Sera from 23 proven or clinically suspected cases of Pneumocystis carinii pneumonitis (PCP) in immunosuppressed patients predominantly with acute lymphoblastic leukaemia, and from 91 normal people, were examined for antibody to P. carinii by indirect immunofluorescence. Low levels of antibody were found in 51 of 91 normal people and elevated or rising titres of antibody in 18 out of 21 cases fr...

متن کامل

Pneumocystis carinii pneumonia diagnosed by non-induced sputum stained with a direct fluorescent antibody.

Non-induced expectorated sputum (NIS) stained with tinctorial stains is not considered useful in the diagnosis of Pneumocystis carinii pneumonia (PCP). The diagnostic yield of NIS was evaluated in human immunodeficiency virus (HIV)-infected patients, when stained with a more sensitive direct fluorescent antibody for PCP-direct fluorescent antibody (PC-DFA). A retrospective analysis was carried ...

متن کامل

A comparison of induced and expectorated sputum for the diagnosis of Pneumocystis carinii pneumonia.

STUDY OBJECTIVES To compare the sensitivities of expectorated and induced sputum for the diagnosis of Pneumocystis carinii pneumonia (PCP). DESIGN Retrospective review. SETTING Academic medical center. PATIENTS Forty-five patients diagnosed as having PCP who had direct fluorescent antibody testing for P carinii on either expectorated or induced sputum. RESULTS Patients were stratified a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied microbiology

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 1974