In vitro integrity of implant external hexagon after application of surgical placement torque simulating implant locking.

نویسندگان

  • Letícia Resende Davi
  • Alexsander Luiz Golin
  • Sérgio Rocha Bernardes
  • Cleudmar Amaral de Araújo
  • Flávio Domingues Neves
چکیده

The aim of this study was to evaluate the integrity of the external hexagon of an implant system with internal and external hexagons but with prosthetic connection through the external hexagon (Internal Torque, IT) in comparison with that of an implant system with external hexagon with mount (External Hexagon, EH). A device was made to measure the rotational freedom angles between implant and abutment hexagons in 10 implants from each group after the application of surgical placement torques of 45, 60 and 80 Ncm simulating implant locking. The distances between the vertices of the external hexagon were also obtained. Rotational freedom data were subjected to ANOVA and Tukey's test (P < .05) showing no significant difference between the angles of the intact implants (EH - 3.31 +/- 0.41 degrees and IT - 3.30 +/- 0.17 degrees ) and after application of a 45 Ncm torque (EH - 3.27 +/- 0.38 degrees and IT - 3.31 +/- 0.22 degrees ). However, after application of a 60 Ncm torque there were significant differences (IT - 3.40 +/- 0.20 degrees and EH - 4.03 +/- 0.54 degrees ). After application of a 80 Ncm torque, the IT implant presented values of 3.39 +/- 0.21 degrees whereas the EH did not support the torque, suffering deformation of its external hexagon. Within the limits of this study, it can be concluded that the IT implant system may be preferable in clinical situations where implant placement within a certain bone density could generate torques higher than 60 Ncm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the External Hexagon Dental Implants after Simulating Surgical Placement and the Rotational Freedom of Implant Components

Currently, there are several possibilities of abutments connections in dental implants. The most common design in use is the external hexagon connection, which, besides the function of transmitting torque at surgical placement, also works as an antirotational mechanism and orientation of the abutment for single tooth prostheses. Several researchers have suggested that screw joint stability is d...

متن کامل

Effect of GapSeal® as a Sealing Material on Microgap and Microleakage at External Hexagon Implant Connections Following Cyclic Loading: An In Vitro Study

Background and Aim: The mismatch of the implant-abutment connection can produce instant stress and microleakage which result in mechanical and biological complications. This study aimed to investigate the influence of GapSeal® as a sealing material on the extent of microgap and microleakage at the external hexagon implant platform following cyclic loading. Materials and Methods: Sixteen implan...

متن کامل

Influence of different maintenance times of torque application on the removal torque values to loosen the prosthetic abutment screws of external hexagon implants.

PURPOSE To analyze the torque application on prosthetic abutment screws using different maintenance times, to determine an influence on the removal torque values. MATERIALS AND METHODS A total of 40 external hexagon implants, 40 titanium screws, and 40 customized abutments were used. In group 1, the screws received a torque of 30 N·cm by instant torque application; in groups 2, 3, and 4, torq...

متن کامل

Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value

Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...

متن کامل

Stability of external and internal implant connections after a fatigue test

OBJECTIVE The objective of this study was to compare the torque and detorque values of screw intermediates of external hexagon, internal hexagon, and Morse taper implants in single restorations before and after mechanical cycling. MATERIALS AND METHODS The study sample was divided into three groups (n = 10) as follows: group EH - external hexagon implant, group IH - internal hexagon implant, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian oral research

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 2008