4D-CT Simulation using Individually Optimized Contrast Enhancement (CE): A Phantom Study

ثبت نشده
چکیده

Innovation/Impact: 4D-CT simulation has been widely used to estimate the respiratory motion of lung tumors and abdominal tumors for radiotherapy planning. However, most abdominal tumors (liver, pancreas etc.) cannot be readily visualized in CT without dynamic CE. It is desirable to combine a 4D-CT without CE and a CE 3D-CT into a CE 4D-CT so that we can both visualize the tumor and estimate its motion in a single scan. Due to the very long scan time of 4D-CT (60-75 s), it is impossible to have peak CE present throughout the entire scan, therefore, one has to set a delay time between the injection of the contrast medium and the start of 4D-CT so that the CE is maximized when scanning the tumor region. In previous studies, the delay time has been set to scan the central part of the tumor at a fixed time from the injection (“A.S. Bedder, 2008, P. Mancosu, 2008”). Such fixed-timing methods did not take into consideration of the large variation in the peak CE time from one patient to another (e.g., 19 – 48 sec for the pancreatic phase, see “L. van Hoe, 1995”) and thus are not optimal for all patients. We propose to use test injection to optimize the delay time in CE 4D-CT for individual patients. To our knowledge, this is the first such study in 4DCT. In this work, we designed a phantom and demonstrated the feasibility of individually optimizing the delay time in CE 4D-CT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom

Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...

متن کامل

Effect of Heart Rate on CT Angiography Using the Enhanced Cardiac Model of the 4D NCAT

We investigate the effect of heart rate on the quality and artifact generation in coronary artery images obtained using multi-slice computed tomography (MSCT) with the purpose of finding the optimal time resolution for data acquisition. To perform the study, we used the 4D NCAT phantom, a computer model of the normal human anatomy and cardiac and respiratory motions developed in our laboratory....

متن کامل

Optimized dynamic contrast-enhanced cone-beam CT for target visualization during liver SBRT

The pharmacokinetic behavior of iodine contrast agents makes it difficult to achieve significant enhancement during contrast-enhanced cone-beam CT (CE-CBCT). This study modeled this dynamic behavior to optimize CE-CBCT and improve the localization of liver lesions for SBRT. We developed a model that allows for controlled study of changing iodine concentrations using static phantoms. A projectio...

متن کامل

Design and Fabrication Process of MTF Phantom CT Scan

Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...

متن کامل

Feasibility and potential benefits of defining the internal gross tumor volume of hepatocellular carcinoma using contrast-enhanced 4D CT images obtained by deformable registration

OBJECTIVE To study the feasibility and the potential benefits of defining the internal gross tumor volume (IGTV) of hepatocellular carcinoma (HCC) using contrast-enhanced 4D CT images obtained by combining arterial-phase (AP) contrast-enhanced (CE) 3D CT and non-contrast-enhanced (NCE) 4D CT images using deformable registration (DR). METHODS Ten HCC patients who had received radiotherapy befo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012