Immunonephelometric determination of retinol-binding protein in serum and urine.
نویسندگان
چکیده
An immunonephelometric method developed for measurement of retinol-binding protein (RBP) in serum and urine can detect it in concentrations of about 30 micrograms/L, which is in the lower limit of its normal concentration in urine (range 0-0.56 mg/L; mean +/- SD 0.19 +/- 0.15; n = 44). Urinary RBP was increased (range 0.93-29.5 mg/L) in all of 25 urine specimens from 13 subjects being treated with aminoglycoside (tobramycin). Urinary excretion of RBP was correlated (r = 0.83) with the excretion of beta 2-microglobulin. The within-assay and day-to-day precision (CV) was determined over the detection range of 0.03-8 mg/L. Within these limits the corresponding CVs varied from 4 to 27% and from 8 to 30%, respectively. The method had fairly good precision within the optimal measuring range of approximately 0.4 to 4.5 mg/L for both urine and 20-fold diluted serum samples. For various RBP concentrations our analytical recovery was 89-114% of added RBP. Results by this method correlated well (r = 0.96, n = 24) with those by a radial immunodiffusion method.
منابع مشابه
Alpha-1 antitrypsin, retinol binding protein and keratin 10 alterations in patients with psoriasis vulgaris, a proteomic approach
Objective(s):Psoriasis is an autoimmune disease that appears on the skin. Although psoriasis is clinically and histologically well characterized, its pathogenesis is unknown in detail. The aims of this study were to evaluate the proteome of psoriatic patients' sera and to compare them with those of normal healthy human to find valuable biomarkers. Materials and Methods: In a case-control study,...
متن کاملLatex immunoassay of retinol-binding protein.
Latex immunoassay, a sensitive method based on latex particle agglutination, is used here for the determination of retinol-binding protein in human biological fluids. The assay, similar to that described previously for beta 2-microglobulin (Clin. Chem. 27:832-837, 1981), consists of incubating the sample at 37 degrees C for 30 min with antibody-coated particles, then quantifying the resulting a...
متن کاملEnzyme-linked immunosorbent assay of retinol-binding protein in serum and urine.
This highly sensitive method for determining retinol-binding protein in human serum and urine is based on a double-antibody "sandwich"-type enzyme-linked immunosorbent assay. The assayable concentration range is 0.8-48 micrograms/L, the detection limit 0.2 micrograms/L. Within-assay coefficients of variation for 10 determinations at two different concentrations were 5.5 and 5.8%. The correspond...
متن کاملA radioimmunoassay for retinol-binding protein in serum and urine.
In this radioimmunoassay for human retinol-binding protein (RBP), sample (serum, diluted as much as 3600-fold; or urine, diluted or undiluted) or calibrant (purified RBP in phosphate buffer containing bovine serum albumin) is incubated with 125I-labeled RBP and rabbit anti-human RBP antiserum for 24 h before separation with second antibody/polyethylene glycol. The assay's sensitivity is 5 micro...
متن کاملMonoclonal antibody-based immunoenzymometric assays of retinol-binding protein.
Retinol-binding protein (RBP) is a low-molecular-mass protein (21 kDa), easily filtered in renal glomeruli and very efficiently reabsorbed by the proximal convoluted tubules (PCTs). In PCT dysfunction, high concentrations of RBP are found in urine. Several methods have been used to determine RBP in serum or urine. We describe the production, selection, labeling, and utilization of anti-RBP mono...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 29 5 شماره
صفحات -
تاریخ انتشار 1983