Ultrasonographically guided insertion of a 15-cm catheter into the deep brachial or basilic vein in patients with difficult intravenous access.

نویسندگان

  • Christopher N Mills
  • Otto Liebmann
  • Michael B Stone
  • Bradley W Frazee
چکیده

STUDY OBJECTIVE Standard length (3 to 5 cm) intravenous catheters in the deep brachial or basilic vein tend to dislodge prematurely. We assess the safety and longevity of a 15-cm catheter inserted in these veins by a novel ultrasonographically guided technique. METHODS This is a prospective cohort study conducted in an urban teaching emergency department (ED). Adult subjects were enrolled if 2 peripheral intravenous insertion attempts had failed. A 3.2-cm, 18-gauge catheter was first inserted into the deep brachial or basilic vein under ultrasonographic guidance. In a separate step, a wire was inserted through this catheter, and a 15-cm, 16-gauge catheter was placed over the wire and left in place for up to 3 days. Primary outcomes were time to securing access and rate of loss of access. Secondary outcomes included complication rates and subject satisfaction. RESULTS Twenty-five subjects were enrolled; 23 catheters were successfully placed. Median time required for initial vein cannulation was 3 minutes (interquartile range [IQR] 2 to 7 minutes) and for securing the 15-cm catheter was an additional 4 minutes (IQR 3 to 5 minutes). Median duration of access was 26 hours (IQR 10 to 47 hours). The only complication was early infiltration in 1 subject. All subjects rated satisfaction as 4 or 5 on a 5-point Likert scale. CONCLUSION We present a promising alternative to central venous catheterization in patients with difficult intravenous access. This technique appears to be fast, safe, and well tolerated by adult patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasound-guided brachial and basilic vein cannulation in emergency department patients with difficult intravenous access.

STUDY OBJECTIVE Emergency department patients who require intravenous access but lack peripheral intravenous sites frequently require central line placement. Blind percutaneous brachial vein cannulation has been proposed as an alternative in these patients but is associated with high failure and complication rates. We evaluated an ultrasound-guided approach to percutaneous deep brachial vein or...

متن کامل

The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections

Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...

متن کامل

Ultrasound-Guided Deep Brachial and Basilic Vein Cannulation in the Emergency Department

Intravenous (IV) access is a common and essential emergency department procedure, which may be challenging in certain patients. Populations notorious for difficult IV access include injection drug users, diabetics, obese patients, or those in hypoperfusion states. Central venous catheter placement becomes the default solution when attempts at peripheral access prove unsuccessful. Yet, many pati...

متن کامل

حل مشکل جاگذاری کاتتر ورید مرکزی با استفاده از کاتتر وریدی: مقاله تکنیکال

Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will ...

متن کامل

Brachial Approach As an Alternative Technique of Fibrin Sheath Removal for Implanted Venous Access Devices

Implanted venous access device (IVAD) late dysfunction is commonly caused by fibrin sheath formation. The standard method of endovascular fibrin sheath removal is performed via the femoral vein. However, it is not always technically feasible and sometimes contraindicated. Moreover, approximately 4-6 h of bed rest is necessary after the procedure. In this article, we describe an alternative meth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of emergency medicine

دوره 50 1  شماره 

صفحات  -

تاریخ انتشار 2007