Thermal conductivity measurements of high and low thermal conductivity films using a scanning hot probe method in the 3ω mode and novel calibration strategies.

نویسندگان

  • Adam A Wilson
  • Miguel Muñoz Rojo
  • Begoña Abad
  • Jaime Andrés Perez
  • Jon Maiz
  • Jason Schomacker
  • Marisol Martín-Gonzalez
  • Diana-Andra Borca-Tasciuc
  • Theodorian Borca-Tasciuc
چکیده

This work discusses measurement of thermal conductivity (k) of films using a scanning hot probe method in the 3ω mode and investigates the calibration of thermal contact parameters, specifically the thermal contact resistance (R(th)C) and thermal exchange radius (b) using reference samples with different thermal conductivities. R(th)C and b were found to have constant values (with b = 2.8 ± 0.3 μm and R(th)C = 44,927 ± 7820 K W(-1)) for samples with thermal conductivity values ranging from 0.36 W K(-1) m(-1) to 1.1 W K(-1) m(-1). An independent strategy for the calibration of contact parameters was developed and validated for samples in this range of thermal conductivity, using a reference sample with a previously measured Seebeck coefficient and thermal conductivity. The results were found to agree with the calibration performed using multiple samples of known thermal conductivity between 0.36 and 1.1 W K(-1) m(-1). However, for samples in the range between 16.2 W K(-1) m(-1) and 53.7 W K(-1) m(-1), calibration experiments showed the contact parameters to have considerably different values: R(th)C = 40,191 ± 1532 K W(-1) and b = 428 ± 24 nm. Finally, this work demonstrates that using these calibration procedures, measurements of both highly conductive and thermally insulating films on substrates can be performed, as the measured values obtained were within 1-20% (for low k) and 5-31% (for high k) of independent measurements and/or literature reports. Thermal conductivity results are presented for a SiGe film on a glass substrate, Te film on a glass substrate, polymer films (doped with Fe nano-particles and undoped) on a glass substrate, and Au film on a Si substrate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Thin Film Isotropic and Anisotropic Thermal Conductivity Using 3ω and Thermoreflectance Imaging

The 3ω method is a well established technique for experimentally extracting thermal conductivity of thin films and substrates. The 3ω method calculates thermal conductivity by measuring thin film temperature response to a metal strip heater deposited on the material’s surface. The electrical resistance of the metal strip is used as both heat source and temperature sensor. An important factor in...

متن کامل

Measurement of thermal conductivity of PbTe nanocrystal coated glass fibers by the 3ω method.

Fiber-based thermoelectric materials can conform to curved surfaces to form energy harvesting devices for waste heat recovery. Here we investigate the thermal conductivity in the axial direction of glass fibers coated with lead telluride (PbTe) nanocrystals using the self-heated 3ω method particularly at low frequency. While prior 3ω measurements on wire-like structures have only been demonstra...

متن کامل

An Improvement in Thermal and Rheological Properties of Water-based Drilling Fluids Using Multiwall Carbon Nanotube (MWCNT)

Designing drilling fluids for drilling in deep gas reservoirs and geothermal wells is a major challenge. Cooling drilling fluids and preparing stable mud with high thermal conductivity are of great concern. Drilling nanofluids, i.e. a low fraction of carbon nanotube (CNT) well dispersed in mud, may enhance the mixture thermal conductivity compared to the base fluids. Thus, they are potentially ...

متن کامل

Improved 3-omega measurement of thermal conductivity in liquid, gases, and powders using a metal-coated optical fiber.

A novel 3ω thermal conductivity measurement technique called metal-coated 3ω is introduced for use with liquids, gases, powders, and aerogels. This technique employs a micron-scale metal-coated glass fiber as a heater/thermometer that is suspended within the sample. Metal-coated 3ω exceeds alternate 3ω based fluid sensing techniques in a number of key metrics enabling rapid measurements of smal...

متن کامل

Measuring the Thermal Conductivity of Thin Films: 3 Omega and Related Electrothermal Methods

This review describes the major electrothermal methods for measuring the thermal conductivity of thin films in both cross-plane and in-plane directions. These methods use microfabricated metal lines for joule heating and resistance thermometry. The 3ω method for crossplane measurements is described thoroughly, along with a related DC method. For in-plane measurements, several methods are presen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nanoscale

دوره 7 37  شماره 

صفحات  -

تاریخ انتشار 2015