The neuroendocrine effects of the TASER X26: a brief report.

نویسندگان

  • D Dawes
  • J Ho
  • J Miner
چکیده

INTRODUCTION Law enforcement officers use conducted electrical weapons (CEW) such as the TASER X26 to control violently resistive subjects. There are no studies in the medical literature examining the effects of these weapons on the human stress response. This is the first study to compare the human stress response to conducted electrical weapons, oleoresin capsicum (O.C.), a cold-water tank immersion, and a defensive tactics drill. METHODS Subjects were randomized to one of the four interventions studied. Subjects received either a 5-s exposure from the TASER X26 CEW with the probes fired into the back from 7 ft, a 5-s spray of O.C., a skin and mucous membrane irritant, to the eyes, a 45-s exposure of the hand and forearm in a 0 degrees C cold water tank, or a 1-min defensive tactics drill. RESULTS Alpha-amylase had the greatest increase from baseline at 10-15 min with the defensive tactics drill. Cortisol had the greatest increase at 15-20 min with O.C. Cortisol remained most elevated at 40-60 min in the defensive tactics drill group. CONCLUSIONS Our preliminary data suggests that physical exertion during custodial arrest may be most activating of the human stress response, particularly the sympathetic-adrenal-medulla axis. This may suggest that techniques to limit the duration of this exertion may be the safest means to apprehend subjects, particularly those at high-risk for in-custody death. Conducted electrical weapons were not more activating of the human stress response than other uses of force.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Defence Scientific Advisory Council Sub-Committee on the Medical Implications of Less-Lethal Weapons (DOMILL) Statement on the Medical Implications of Use of the Taser X26 and M26 Less-Lethal Systems on Children and Vulnerable Adults

2. DOMILL has issued five previous statements relating to the medical implications of the Taser M26 and Taser X26 less-lethal systems. 4 The Taser X26 conducted energy device was introduced into UK policing in 2005 as a replacement for the Taser M26. Recent data from the Home Office Centre for Applied Science and Technology (CAST) indicate that the Taser X26 is the device primarily in use by th...

متن کامل

Repetitive TASER X26 discharge resulted in adverse physiologic events with a dose-response relationship related to the duration of discharge in anesthetized swine model.

The objectives of our study were to investigate the dose-response relationship of the TASER X26 discharge duration in an anesthetized swine model. Fourteen swines were anesthetized and then exposed to TASER X26 discharge for 5 sec (n = 5) or for 10 sec (n = 6). The sham control group (n = 3) was anesthetized and studied using the same protocol except TASER X26 discharges during the experiments....

متن کامل

Can the direct cardiac effects of the electric pulses generated by the TASER X26 cause immediate or delayed sudden cardiac arrest in normal adults?

There is only a small amount of experimental data about whether the TASER X26, a nonlethal weapon that delivers a series of brief electrical pulses to cause involuntary muscular contraction to temporarily incapacitate an individual, can initiate ventricular fibrillation to cause sudden cardiac arrest either immediately or sometime after its use. Therefore, this paper uses the fundamental law of...

متن کامل

Muscle contraction during electro-muscular incapacitation: A comparison between square-wave pulses and the TASER(®) X26 Electronic control device.

Electronic control devices (including the Advanced TASER(®) X26 model produced by TASER International) incapacitate individuals by causing muscle contractions. To provide information relevant to development of future potential devices, effects of monophasic square waves with different parameters were compared with those of the X26 electronic control device, using two animal models (frogs and sw...

متن کامل

Echocardiographic evaluation of TASER X26 probe deployment into the chests of human volunteers.

Several animal studies have shown that the TASER X26 (TASER International, Scottsdale, Ariz) conducted electrical weapon can electrically capture the myocardium when discharged on the thorax. These results have not been reproduced in human echocardiographic studies. A primary limitation of those human studies is that the TASER device was connected by taping the wires into conductive gel on the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Forensic science international

دوره 183 1-3  شماره 

صفحات  -

تاریخ انتشار 2009