Binding of annexin V to plasma membranes of human spermatozoa: a rapid assay for detection of membrane changes after cryostorage.

نویسندگان

  • H J Glander
  • J Schaller
چکیده

When the cell membrane is disturbed, phospholipid phosphatidylserine (PS) is translocated from the inner to the outer leaflet of the plasma membrane. This is one of the earliest signs of apoptosis and can be monitored by the calcium-dependent binding of annexin V. Therefore, annexin V-binding, in conjunction with flow cytometry, was used to evaluate the integrity of the sperm plasma membrane after different cryostorage protocols: i.e. 10% (v/v) glycerol; sperm maintenance medium (MM); freezing medium TEST yolk buffer (TYB); or cryostorage without protection (cryoshock). Using a combination of two fluorescent dyes, annexin V and propidium iodide (PI), led to three groups of spermatozoa being identified: (i) viable spermatozoa (annexin V-negative and PI-negative); (ii) dead spermatozoa (annexin V-positive and PI-positive); and (iii) cells with impaired but integer plasma membrane (annexin V-positive and PI-negative). The percentage of vital annexin V-negative spermatozoa increased significantly (P < 0.05) from spermatozoa treated by cryoshock (15.0+/-1.2%) to spermatozoa cryopreserved by TYB (26.6+/-2.2%) via cryopreservation by 10% (v/v) glycerol (19.9+/-1.6%) and by MM (22.2 1.8%) and was associated with the percentage of motile spermatozoa (17.6+/-3.4% by glycerol; 19.6+/-3.7% by MM and 22.6+/-3.9% by TYB; P = 0.0001). Of the spermatozoa, 12-22% were annexin V-positive even though they did not bind to PI, indicating viability before as well as after cryostorage. The percentage of vital annexin V-positive spermatozoa was significantly correlated with different sperm motility parameters (velocity straight linear, r = 0.601, P = 0.018; percentage of linearly motile spermatozoa: r = 0.549, P = 0.034). We, therefore, concluded that annexin V-binding is more sensitive in detecting a deterioration of membrane functions than PI staining, and that a considerable percentage of spermatozoa might have dysfunctional plasma membranes besides dead or moribund cells. Of the cryopreservation protocols tested, TYB yielded the most viable spermatozoa. Therefore, we advocate the use of the annexin V-binding assay for the evaluation of the quality and integrity of spermatozoa.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

O-2: The Effect of Age on the Expression of Apoptosis Biomarkers in Human Spermatozoa

Background: The negative impact of age on reproductive success has been well demonstrated for women, but age-related changes in the male reproductive system appear to be more subtle. Diminishing testicular function is indicated by a decline in testosterone levels, accompanied by an increase in gonadotropins. Some studies have shown increased age-related numerical and structural sperm chromosoma...

متن کامل

P-56: Effect of Cissampelos Capensis Rhizome Extract on Human Sperm Capacitation and Acrosome Reaction

s:2086:"Background: Cissampelos capensis, is commonly known by the Afrikaans name "dawidjies" and is the most important and best known medicinal plant of the family Menispermaceae used by the Khoisan and other rural people in the western regions of South Africa. Among numerous other ailments, it is taken to treat male fertility problems. The aim of this study was to investigate the effects of C...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Molecular human reproduction

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 1999