Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists.
نویسندگان
چکیده
OBJECTIVE This study tested whether the two-body wear of monolithic zirconia and their corresponding enamel antagonists was higher compared to monolithic alloy and veneered zirconia. MATERIALS AND METHODS Cylindrical specimens (N = 36, n = 6) were prepared out of (A) veneered zirconia (VZ), (B) glazed zirconia using a glaze ceramic (GZC), (C) glazed zirconia using a glaze spray (GZS), (D) manually polished monolithic zirconia (MAZ), (E) mechanically polished monolithic zirconia (MEZ) and (F) monolithic base alloy (control group, MA). Wear tests were performed in a chewing simulator (49 N, 1.7 Hz, 5°C/50°C) with enamel antagonists. The wear analysis was performed using a 3D profilometer before and after 120,000, 240,000, 640,000 and 1,200,000 masticatory cycles. SEM images were used for evaluating wear qualitatively. The longitudinal results were analysed using linear mixed models (α = 0.05). RESULTS Materials (p < 0.001) and number of masticatory cycles (p < 0.001) had a significant effect on the wear level. The least enamel antagonist wear was observed for MAZ and MEZ (27.3 ± 15.2, 28 ± 11.1 μm, respectively). GZC (118 ± 30.9 μm) showed the highest wear of enamel antagonists. The highest wear rate in the material was observed in GZS (91.3 ± 38.6 μm). While in the groups of MA, VZ, GZC and GZS 50% of the specimens developed cracks in enamel, it was 100% in MAZ and MEZ groups. CONCLUSION Polished monolithic zirconia showed lower wear rate on enamel antagonists as well as within the material itself but developed higher rates of enamel cracks.
منابع مشابه
Monolithic zirconia: A review of the literature
Veneer cracking or chipping is the major complication of the zirconia based restorations. Monolithic zirconia has been introduced to overcome this problem, as well as to use in patients with limited interocclusal space. Many research articles on monolithic zirconia crowns have been published in the last years. The aim of this review article was to present data about the wear, surface roughness,...
متن کاملWear performance of monolithic dental ceramics with different surface treatments.
OBJECTIVE To investigate the two-body wear performance of monolithic dental ceramics with different surface treatments. METHOD AND MATERIALS Standardized specimens (n = 8/ series) were fabricated from three monolithic dental ceramics (experimental translucent zirconia, experimental shaded zirconia, lithium disilicate). Four groups of each material were defined according to clinically relevant...
متن کاملA study on the wear of enamel caused by monolithic zirconia and the subsequent phase transformation compared to two other ceramic systems
PURPOSE The purpose of this in vitro research project was to evaluate and compare the wear behavior of human tooth enamel opposing monolithic zirconia and other different ceramic restorative materials and also to observe the tetragonal to monoclinic phase transformation in zirconia-based ceramics that may occur while simulating wear occurring at room temperature in a wet environment. MATERIAL...
متن کاملIn vitro failure and fracture resistance of veneered and full-contour zirconia restorations.
OBJECTIVES This study evaluated the failure and fracture resistance of zirconia-based fixed partial dentures (FPDs) under the influence of different surface treatments and adjustment procedures. METHODS Seven groups (n=8/group) of three-unit zirconia-based FPDs were fabricated in anatomic design (AD) or anatomically reduced design (ARD) and surfaces were prepared according to clinical relevan...
متن کاملWear of enamel opposing zirconia and lithium disilicate after adjustment, polishing and glazing.
OBJECTIVES To compare the wear and opposing enamel wear of adjusted (A); adjusted and polished (AP); and adjusted and glazed (AG) zirconia and lithium disilicate. METHODS Specimens (n=8) were prepared of lithium disilicate (A, AP, and AG), zirconia (A, AP, and AG), veneering porcelain, and enamel (control). Surface roughness was measured for each ceramic. In vitro wear was conducted in the UA...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta odontologica Scandinavica
دوره 71 1 شماره
صفحات -
تاریخ انتشار 2013