The Sterility and Sterilization of Lung Ventilators.
نویسندگان
چکیده
Intermittent positive pressure breathing machines are in use for the treatment of many respiratory and cardiac conditions, but there is no agreement regarding the risk of cross infection and the necessity of sterilizing part, or all, of this equipment. Until recently, complete sterilization has been difficult to effect, and so reliance has been placed on boiling or chemical disinfection of the breathing tubing only. During an outbreak of unexplained post-operative respiratory complications in one respiratory unit amongst patients who had been ventilated on positive pressure breathing machines, the same organisms were found to be common to both the patients and the machines. We therefore investigated this to see whether, if machines become infected by patients, prevention is possible. For the experiments sterile Radcliffe positive negative ventilators were used. Complete sterilization can be achieved by exposing a machine to a mixture of 10% ethylene oxide gas in an atmosphere of carbon dioxide over a period of time, provided that the machine is run continuously during the process so that the gas permeates all parts (Baker and Seaber, 1962). The complete machine, with the breathing tubes detached and the humidifier empty, is placed in a large plastic bag, which is made gas-tight with special zip fasteners, and the electric cable is led to a suitable power point through a sleeve in the bag. Air is exhausted from the bag as far as possible by applying suction from a domestic vacuum cleaner. The bag is filled with the mixture of ethylene oxide and carbon dioxide and sealed, and the machine is run in this atmosphere for 12 hours. The apparatus is then removed and, with the machine still running, flushed through with air for two hours. The efficacy of this method has been checked by deliberately infecting machines with a 24-hr. broth culture of Staphylococcus aureus of known phage type, which was sprayed on to the inner surfaces of all components of the ventilators. After sterilization, swabs were taken from all the infected parts, plated on to a blood agar plate, and inoculated into tubes of nutrient broth. On no occasion was any growth detected, although controls set up at the same time and not exposed to ethylene oxide all showed growth. Flushing with air after sterilization was necessary in order to remove all traces of ethylene oxide. This gas is absorbed on to the surface of rubber and some plastic materials and might be given off into the breathing circuit later. The time of two hours (Fig. 1) was determined by frequent sampling of the effluent and estimating the ethylene oxide by a standard gas detector method (H.M.S.O., 1951).
منابع مشابه
Terminal Sterilization and Potential for Parametric Release
S tcrility of a drug product, in the strictest sense, is defined as "complete absence of microorganisms in the product." However, the test for sterility as described in the Pharmacopoeias [I], is not a test on which any strong reliance can be based tor sterility assurance of the product. Due to limitations in testing [2]. the test for sterility is not a suitable release test to verify that a pr...
متن کاملاستفاده همزمان از دو ونتیلاتور برای درمان عوارض ریوی ناشی از تهویه مکانیکی در بیمار مولتیپل تروما: گزارش مورد
Background and Objective: Some of multiple trauma patients admitted in ICU (Intensive Care Unit) are intubated and ventilated by mechanical ventilation. These patients are prone to many complications such as lung disease. Reasons for this complication are patients without any movement, incomplete cough reflex, GI aspiration and then not a good pulmonary discharge prone the lungs of patients to ...
متن کاملP-147: Ovarian Function over Time in Adult Rats after Tubal Sterilization
Background: Tubal sterilizatio (TS) is a widely applied contraceptive method worldwide. Although most studies have described sterilization as a safe method, there are reports of TS complications. The aim of this study was to evaluate the effects of TS on ovarian function. Materials and Methods: The study comprised of 2 protocols A and B. A Protocol: survey ovarian hormone and B protocol: study ...
متن کاملSterility testing: the control of efficiency of sterilization techniques.
During the course of an investigation of cotton for use as air filters on the needles of bleeding units, a heat-resistant, spore-forming organism was isolated. Because of its unusual degree of heat resistance, the organism appeared to be more suitable as a control of the efficiency of sterilization than species of Clostridium usually employed for this purpose. Experiments were undertaken to det...
متن کاملSterility Assurance with Filtration Taking Bioburden, Membrane Integrity, and Process Conditions into Account
LEVEL: INTERMEDIATE U nder ideal conditions, the result of a sterility test reflects the presence or absence of viable organisms in the samples analyzed. However, it has long been recognized that inferences regarding sterility (whether for a batch of inprocess material or a finished dosage form) are subject to statistical limitations. The probability (P) of detecting contamination in a given ba...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Thorax
دوره 18 شماره
صفحات -
تاریخ انتشار 1963