Continuous Monitoring of pH using Ion-selective Field Effect Transistors (ISFET’s) Operating with a Fixed Bias Applied to the Reference Electrode
نویسنده
چکیده
A method for correction of threshold voltage drift in pH-sensitive ion-selective field effect transistors (ISFET’s) is presented. The proposed method allows accurate continuous monitoring of pH under clinical conditions corresponding to rapid pH changes such as those encountered in acute metabolic acidosis and cardiopulmonary bypass operations. This method, which involves monitoring the differential of drain current in the current mode of ISFET operation with a constant potential applied to the reference electrode, can also be of advantage in telemetry applications requiring low-power consumption. In the current mode the inherent device instability resulting from a drift in the threshold voltage of the ISFET manifests as a relatively slow, monotonic decrease in the measuring signal, namely the drain current. Ordinarily, over sufficiently small intervals of time the variation in the measuring signal due to drift is essentially negligible in applications where changes in pH are abrupt. Consequently, the differential of the measuring signal represents only the changes in the pH if the device sensitivity is adequately high. The validity of the proposed method is examined using a Si3N4-gate pH-sensitive ISFET to monitor pH variations in the 3.5-10.0 range. Key-Words: ISFET, pH, Drift, Instability, Continuous monitoring
منابع مشابه
Construction of S?-Selective Electrode and Thermodynamic Study of the Ternary Aqueous Mixed Electrolyte System (SrCl2, KG, H20) Using Potentiometric Method
In order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (NPDBH) was used as an ionophore. This electrode responds to Sr (II)ion with a sensitivity of 28.2 ± 0.5 mV/decade over the range 1.0 x 10-6 to 1.0 Mat pH 3.0-10.0. Thelimit of detection was 2.4 x 10-7 M. The influences of membrane composition, the pH of the t...
متن کاملIodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex
An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...
متن کاملHigh-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium
N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...
متن کاملIon Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation
Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The...
متن کامل(1E,2E) -bis (2-aminophenyl) N'1,N'2-dihydroxyethane bis (imidothioate) as a neutral carrier in ion-selective electrode for Ni(II) and it computational studies
A PVC membrane Ni(II) ion selective electrode has been constructed using (1E,2E)-bis(2-aminophenyl)N'1,N'2-dihydroxyethanebis as membrane carrier. The electrode exhibited a goodpotentiometric response for Ni(II) over a wide concentration range 1.0×10-4 to 1.0×10-1M with aslope of 29.4±0.5 mV/decade a and a working pH range of 6.5-9.0. It had a fast response time of≤20s. The best performance was...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015